Connectivity Guide
CMC Server Information
The following MIB tables provide CMC server information being monitored by the chassis management controller.
Table 199. DRsServerIndex
Name
drsServerIndex
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.1
Description Defines the index (one-based) of the associated CMC server.
Syntax DellCMCServerIndexRange
Access Read-only
Table 200. DRsServerMonitoringCapable
Name
drsServerMonitoringCapable
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.2
Description Defines the monitoring capabilities, or the absence of a server in this location.
Syntax DellCMCServerCapable
Access Read-only
Table 201. DRsServerServiceTag
Name
drsServerServiceTag
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.3
Description Defines the Service Tag of the CMC server.
Syntax DellString
Access Read-only
Table 202. DRsServerSlotName
Name
drsServerSlotName
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.4
Description Defines the slot name of the CMC server.
Syntax DellString
Access Read-only
Table 203. DRsServerSlotNumber
Name
drsServerSlotNumber
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.5
Description Defines the chassis slot number of the CMC server.
Syntax DellString
Access Read-only
Table 204. DRsServerNodeID
Name
drsServerNodeID
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.6
Description Defines the Node ID of the CMC server. The Node ID provides a unique identifier for the
server.
44 Chassis Management Controller Group