Connectivity Guide

Table 623. Alert Message Arguments (continued)
quotes found within a message argument string are preprocessed and changed to single
quotes.
Syntax StringType
Table 623. Alert Message Arguments
Access Read-only
Table 624. Alert Chassis Service Tag
Variable Name
alertChassisServiceTag
Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0
Description For modular systems, the service tag of the enclosing chassis. For rack and tower
systems, this varbind will be empty (zero length).
Syntax DisplayString
Table 624. Alert Chassis Service Tag
Access Read-only
Table 625. Alert Chassis Name
Variable Name
alertChassisName
Object ID 1.3.6.1.4.1.674.10892.5.3.1.10.0
Description For modular systems, the chassis name of the enclosing chassis. For rack and tower
systems, this varbind will be empty (zero length).
Syntax DisplayString
Table 625. Alert Chassis Name
Access Read-only
Table 626. Alert Rac FQDN
Variable Name
alertRacFQDN
Object ID 1.3.6.1.4.1.674.10892.5.3.1.11.0
Description Fully qualified domain name of the remote access card.
Syntax StringType
Table 626. Alert Rac FQDN
Access Read-only
System Trap Group
The System Trap Group contains traps that fall under the System Health event category of the iDRAC. System Health traps are
traps those are generally generated in response to events related to the hardware of the system in which an iDRAC resides.
Table 627. Amperage Probe Traps
TrapID Description Category SubCategory Severity
Amperage Probe Normal
2179 Current sensor reading is within
range.
System Health Amperage Informational
Amperage Probe Warning
140 iDRAC MIB