Connectivity Guide
Table 606. Enclosure Temperature Probe Name (continued)
Syntax DisplayString
Access read-only
Table 607. Enclosure Temperature Probe State
Name
enclosureTemperatureProbeState
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4
Description The current state of this temperature probe. Possible states:
1. The current state could not be determined
2. The temperature probe is operating normally
3. The temperature probe has encountered a hardware problem or is not
responding
4. The temperature probe is no longer connected to the enclosure or there
exists a problem communicating to it
5. The temperature probe is unstable
6. The temperature probe is Over Warning Temperature
7. The temperature probe is Under Warning Temperature
Syntax INTEGER
Access read-only
Table 608. Enclosure Temperature Probe Min Warning Value
Name
enclosureTemperatureProbeMinWarningValue
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7
Description The minimum temperature that will force the probe into a warning state.
Syntax INTEGER
Access read-only
Table 609. Enclosure Temperature Probe Min Critical Value
Name
enclosureTemperatureProbeMinCriticalValue
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8
Description The maximum temperature that will force the probe into a warning state.
Syntax INTEGER
Access read-only
Table 610. Enclosure Temperature Probe Max Warning Value
Name
enclosureTemperatureProbeMaxWarningValue
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.9
Description The maximum temperature that will force the probe into a warning state.
Syntax INTEGER
Access read-only
Table 611. Enclosure Temperature Probe Max Critical Value
Name
enclosureTemperatureProbeMaxCriticalValue