CLI Guide

Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Input
racadm getsensorinfo
racadm getsensorinfo -c
Where, -c—Compact output format
Example
racadm getsensorinfo
<senType> <Num> <sensorName> <status> <reading> <units>
<LC> <UC> <PWM>
FanSpeed 1 Fan-1 Not OK N/A rpm N/
A N/A 0
FanSpeed 2 Fan-2 OK 17166 rpm N/
A N/A 100
FanSpeed 3 Fan-3 OK 17250 rpm N/
A N/A 100
FanSpeed 4 Fan-4 OK 17096 rpm N/
A N/A 100
FanSpeed 5 Fan-5 OK 14513 rpm N/
A N/A 100
FanSpeed 6 Fan-6 Not OK N/A rpm N/
A N/A 0
FanSpeed 7 Fan-7 OK 14510 rpm N/
A N/A 100
FanSpeed 8 Fan-8 OK 14479 rpm N/
A N/A 100
FanSpeed 9 Fan-9 OK 14484 rpm N/
A N/A 100
<senType> <Num> <sensorName> <status> <reading>
<units> <LC> <UC>
Temp 1 Chassis Inlet Temperature OK 27
Celsius -7 47
<senType> <Num> <sensorName> <status>
<health>
PWR 1 PS-1 Online OK
PWR 2 PS-2 Input Lost Not
OK
PWR 3 PS-3 Slot Empty N/A
PWR 4 PS-4 Online OK
PWR 5 PS-5 Configuration Error Not
OK
PWR 6 PS-6 Slot Empty N/A
racadm getsensorinfo -c
Sensor Type: Fan
<Num> <sensorName> <status> <reading> <LC> <UC>
1 Fan-1 Not OK N/A rpm N/A N/A
2 Fan-2 OK 17174 rpm N/A N/A
3 Fan-3 OK 17238 rpm N/A N/A
4 Fan-4 OK 17081 rpm N/A N/A
5 Fan-5 OK 14499 rpm N/A N/A
6 Fan-6 Not OK N/A rpm N/A N/A
7 Fan-7 OK 14502 rpm N/A N/A
8 Fan-8 OK 14505 rpm N/A N/A
20
RACADM sub command details