CLI Guide
Synopsis
racadm getpbinfo
Input
racadm getpbinfo
Example
racadm getpbinfo
[Power Budget Status]
System Input Power = 615 W (2098 BTU/h)
Peak System Power = 628 W (2142 BTU/h)
Peak System Power Timestamp = 11:37:36 08/08/2018
Minimum System Power = 606 W (2067 BTU/h)
Minimum System Power Timestamp = 10:16:08 08/06/2018
Overall Power Health = Not OK
Redundancy = No
System Input Power Cap = Disabled
Redundancy Policy = None
Dynamic PSU Engagement Enabled = Not Applicable
System Input Max Power Capacity = 11571 W
Input Redundancy Reserve = Not Applicable
Input Power Allocated to Servers = Not Applicable
Input Power Allocated to Chassis Infrastructure = Not Applicable
Total Input Power Available for Allocation = 2385 W (8137 BTU/h)
Standby Input Power Capacity = Not Applicable
Server Based Power Management Mode = Not Applicable
Max Power Conservation Mode = Not Applicable
Server Performance Over Power Redundancy = Not Applicable
Power Available for Server Power-on = Not Applicable
Extended Power Performance(EPP) Status = Not Applicable
Available Power in EPP Pool = Not Applicable
Used Power in EPP Pool = Not Applicable
EPP Percent - Available = Not Applicable
[Chassis Power Supply Status Table]
<Name> <Model> <Power State> <Input Current> <Input
Volts> <Output Rated
Power>
PS1 PSU.Slot.1 Online 1.55 A 226
V 3000
W
PS2 PSU.Slot.2 Online 1.57 A 227
V 3000 W
PS3 PSU.Slot.3 Online 1.65 A 227
V 3000
W
PS4 PSU.Slot.4 Slot Empty N/A N/
A N/A
PS5 PSU.Slot.5 Slot Empty N/A N/
A N/
A
PS6 PSU.Slot.6 Slot Empty N/A N/
A N/A
[Server Module Power Allocation Table]
<Slot#> <Server Name> <Power State> <Allocation>
<Priority> <Blade Type>
1 SLOT-1 ON 605 W
1 PowerEdge MX840c
2 Extension (1) N/A N/A N/
A N/A
3 SLOT-3 ON 792 W
1 PowerEdge MX840c
4 Extension (3) N/A N/A N/
18
RACADM sub command details