Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition Version 1.00.10 for PowerEdge MX7000 Chassis User's Guide
- Overview
- Updating the management module firmware
- Logging in to OME-Modular
- Logging in to OME–Modular as local, Active Directory, or LDAP user
- OME-Modular home page
- Viewing device health
- Setting up chassis
- Initial configuration
- Configuring chassis settings
- Managing chassis
- Chassis groups
- Controlling chassis power
- Backing up chassis
- Restoring chassis
- Exporting chassis profiles
- Managing chassis failover
- Troubleshooting in chassis
- Blinking LEDs
- Interfaces to access OME-Modular
- Viewing chassis hardware
- Viewing chassis alerts
- Viewing chassis hardware logs
- Configuring OME–Modular
- Managing compute sleds
- Managing Storage
- Managing templates
- Managing identity pools
- Ethernet IO Modules
- MX scalable fabric architecture
- SmartFabric Services
- Managing networks
- Managing Fibre Channel IOMs
- Managing firmware
- Monitoring alerts and logs
- Monitoring audit logs
- Troubleshooting
- Storage
- Firmware update is failing
- Storage assignment is failing
- SAS IOM status is downgraded
- SAS IOM health is downgraded
- Drives on compute sled are not visible
- Storage configuration cannot be applied to SAS IOMs
- Drives in OpenManage are not visible
- iDRAC and OpenManage drive information do not match
- The assignment mode of storage sled is unknown
- Storage
- Recommended slot configurations for IOMs
Monitoring jobs
You can view the status of and details of jobs that are initiated in the chassis and its subcomponents, on the Jobs page. The
jobs include firmware update and inventory refresh for devices.
To view the Jobs page, from the menu bar, click Monitor > Jobs.
You can perform the following tasks on the Jobs page:
● Filter jobs using Advanced Filter
● View a summary of the job.
● Run jobs
● Stop jobs
● Enable jobs
● Disable jobs
● Delete jobs
The job status is "Completed with errors", when one ore more sub-tasks fail the request and the status is set to "Warning". If all
the sub tasks fail, status is "Failed". If all the tasks are completed successful, the status is displayed as "Completed".
NOTE: When the "Lockdown mode" is enabled on iDRAC, the Blink LED job status for iDRAC is displayed as "failed" on the
OME–Modular Jobs page, even though the job is successful in iDRAC.
Filtering jobs
To filter jobs:
1. On the Jobs page, click Advanced Filter.
2. Select or update the following based on your requirement:
● Status—To view jobs based on status. The available options are:
○ Scheduled
○ Queued
○ Starting
○ Running
○ Completed
○ Failed
○ New
○ Completed with errors
○ Aborted
○ Paused
○ Stopped
○ Canceled
● State—To view jobs based on state. The available options are:
○ Enabled
○ Disabled
● Job Type—To view jobs based on the type. The available options are:
○ Debug Logs
○ Settings Update
○ Software Rollback
○ Device Action
○ Restore
○ Device Config
○ Chassis Profile
○ Inventory
○ Update
○ MCM OffBoarding
○ Backup
○ Profile Update
○ Quick Deploy
80
Monitoring audit logs