Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition Version 1.00.10 for PowerEdge MX7000 Chassis User's Guide
- Overview
- Updating the management module firmware
- Logging in to OME-Modular
- Logging in to OME–Modular as local, Active Directory, or LDAP user
- OME-Modular home page
- Viewing device health
- Setting up chassis
- Initial configuration
- Configuring chassis settings
- Managing chassis
- Chassis groups
- Controlling chassis power
- Backing up chassis
- Restoring chassis
- Exporting chassis profiles
- Managing chassis failover
- Troubleshooting in chassis
- Blinking LEDs
- Interfaces to access OME-Modular
- Viewing chassis hardware
- Viewing chassis alerts
- Viewing chassis hardware logs
- Configuring OME–Modular
- Managing compute sleds
- Managing Storage
- Managing templates
- Managing identity pools
- Ethernet IO Modules
- MX scalable fabric architecture
- SmartFabric Services
- Managing networks
- Managing Fibre Channel IOMs
- Managing firmware
- Monitoring alerts and logs
- Monitoring audit logs
- Troubleshooting
- Storage
- Firmware update is failing
- Storage assignment is failing
- SAS IOM status is downgraded
- SAS IOM health is downgraded
- Drives on compute sled are not visible
- Storage configuration cannot be applied to SAS IOMs
- Drives in OpenManage are not visible
- iDRAC and OpenManage drive information do not match
- The assignment mode of storage sled is unknown
- Storage
- Recommended slot configurations for IOMs
Table 4. Fabric topology
Chassis Slot Module
Chassis 1 A1 MX9116n FSE
A2 MX7116n FEM
Chassis 2 A1 MX7116n FEM
A2 MX9116n FSE
Chassis 3-10 A1 MX7116n FEM
A2 MX7116n FEM
You can also use Fabric B to create a second scalable fabric:
Restrictions and guidelines
The following restrictions and guidelines are applicable when building a scalable fabric:
● Mixing switch types in the same fabric is not supported. For example: MX9116n in slot A1 and MX5108n in slot A2
● Mixing switch types across fabrics is supported. For example: MX9116n in slots A1& A2 and MX5108n in slots B1 & B2
● All FSE and FEM IOMs in a scalable fabric must be in the same OME–Modular MCM group. FEMs in a chassis in MCM group
1 cannot be connected to FSEs in a chassis in MCM group 2.
The following restrictions are applicable when implementing a scalable fabric in both fabric slot A and fabric slot B:
● IOM placement for each scalable fabric must be the same within the same chassis. For example, if the FSE for the first
scalable fabric is in Slot A1, then the second FSE must be in slot B1 in the same chassis, and so on.
56