Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition Version 1.00.10 for PowerEdge MX7000 Chassis User's Guide
- Overview
- Updating the management module firmware
- Logging in to OME-Modular
- Logging in to OME–Modular as local, Active Directory, or LDAP user
- OME-Modular home page
- Viewing device health
- Setting up chassis
- Initial configuration
- Configuring chassis settings
- Managing chassis
- Chassis groups
- Controlling chassis power
- Backing up chassis
- Restoring chassis
- Exporting chassis profiles
- Managing chassis failover
- Troubleshooting in chassis
- Blinking LEDs
- Interfaces to access OME-Modular
- Viewing chassis hardware
- Viewing chassis alerts
- Viewing chassis hardware logs
- Configuring OME–Modular
- Managing compute sleds
- Managing Storage
- Managing templates
- Managing identity pools
- Ethernet IO Modules
- MX scalable fabric architecture
- SmartFabric Services
- Managing networks
- Managing Fibre Channel IOMs
- Managing firmware
- Monitoring alerts and logs
- Monitoring audit logs
- Troubleshooting
- Storage
- Firmware update is failing
- Storage assignment is failing
- SAS IOM status is downgraded
- SAS IOM health is downgraded
- Drives on compute sled are not visible
- Storage configuration cannot be applied to SAS IOMs
- Drives in OpenManage are not visible
- iDRAC and OpenManage drive information do not match
- The assignment mode of storage sled is unknown
- Storage
- Recommended slot configurations for IOMs
NOTE: For tagged or untagged VLAN network, any IPv6 setting configured using OME - Modular may not have
the default gateway. To get the default gateway, go to the respective OS10 CLI and enable Stateless Address
Autoconfiguration (SLAAC) on the respective tagged or untagged VLAN.
7. In the DNS Server Settings section, enter the Preferred DNS Server, Alternate DNS Server 1, and Alternate DNS
Server 2 addresses.
For MXG610s IOMs, you can set the Preferred DNS and Alternate Server 1 and 2 addresses. However, the server address
for Alternate DNS Server 2 is not applied though the response is successful as, MXG610s IOMs support only two server
address for DNS settings.
8. In the Management VLAN section, select Enable VLAN and enter the VLAN ID.
For MXG610s FC IOMs, DHCP works only without VLAN while Static IP works with or without VLAN configuration. To
change the IP configuration from DHCP IP to Static IP, perform the following steps:
a. Disable DHCP, configure the static IP, and save the configuration.
b. Enable VLAN, configure the VLAN ID, and save the configuration.
Configuring root password
To configure the root password:
1. Click All Devices > I/O Modules > View Details > Settings > Management or Devices > I/O Modules > View Details >
Settings > Management.
The I/O Modules page is displayed.
2. Enter the Host Name and Root Password for the IOM.
Configuring SNMP settings
To configure the SNMP settings:
1. Click All Devices > I/O Modules > View Details > Settings > Monitoring or Devices > I/O Modules > View Details >
Settings > Monitoring.
2. Select Enable SNMP to configure the SNMP version and community string.
Configuring advanced settings
To configure the advanced IOM settings:
1. Click All Devices > I/O Modules > View Details > Settings > Advanced or Devices > I/O Modules > View Details >
Settings > Advanced.
2. Select the options to replicate the chassis time and alert settings to the IOM.
Configuring ports
You can configure breakout, admin status, and MTUs for IOMs. You can configure breakout only for port groups.
NOTE: The port description is applicable only to full-switch mode IOMs. Update the port description in the IOM CLI.
NOTE: Ensure that the peer FC port has a fixed speed and matches the speed of the IOM FC port for the link to come up.
To configure breakout:
1. Click Devices > I/O Modules > View Details > Hardware > Port Information.
2. Select the port group and click Configure Breakout.
The Configure Breakout window is displayed.
3. Select the Breakout Type.
First apply "Hardware Default" and then select the required breakout.
NOTE: Breakouts can be configured only for Fabric Mode IOMs.