Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition Version 1.00.10 for PowerEdge MX7000 Chassis User's Guide
- Overview
- Updating the management module firmware
- Logging in to OME-Modular
- Logging in to OME–Modular as local, Active Directory, or LDAP user
- OME-Modular home page
- Viewing device health
- Setting up chassis
- Initial configuration
- Configuring chassis settings
- Managing chassis
- Chassis groups
- Controlling chassis power
- Backing up chassis
- Restoring chassis
- Exporting chassis profiles
- Managing chassis failover
- Troubleshooting in chassis
- Blinking LEDs
- Interfaces to access OME-Modular
- Viewing chassis hardware
- Viewing chassis alerts
- Viewing chassis hardware logs
- Configuring OME–Modular
- Managing compute sleds
- Managing Storage
- Managing templates
- Managing identity pools
- Ethernet IO Modules
- MX scalable fabric architecture
- SmartFabric Services
- Managing networks
- Managing Fibre Channel IOMs
- Managing firmware
- Monitoring alerts and logs
- Monitoring audit logs
- Troubleshooting
- Storage
- Firmware update is failing
- Storage assignment is failing
- SAS IOM status is downgraded
- SAS IOM health is downgraded
- Drives on compute sled are not visible
- Storage configuration cannot be applied to SAS IOMs
- Drives in OpenManage are not visible
- iDRAC and OpenManage drive information do not match
- The assignment mode of storage sled is unknown
- Storage
- Recommended slot configurations for IOMs
6. In the Restore File Password section, enter the Encryption Password to open the encrypted back up file.
7. Click Restore to restore the chassis.
A message is displayed indicating that the chassis is successfully restored.
You can check the status and details of the restore process on the Montitoring > Jobs page.
Exporting chassis profiles
You can export chassis profiles for cloning the settings to other chassis.
To export the chassis profile:
1. On the OME–Modular home page, click More Actions > Export Profile.
The Export Profile window is displayed.
2. Select the Share Type.
3. Enter the network share address and path.
4. If the Share Type is CIFS, enter the Domain, User Name, and Password to access the shared location.
5. Click Export.
Managing chassis failover
Failover is applicable in dual management module configuration and is the process of transferring the active role to the standby
management module. Reboot the active management module and re-initialize the stand-by management module to assume the
active role. The failover operation takes up to 10 minutes for completion. OME–Modular is unavailable during this process. You
must have the chassis administrator privilege to start a failover.
NOTE: After a failover, the chassis management performance returns to normal in a few minutes.
NOTE: During a failover, the chassis power state on the OME–Modular GUI is displayed as "off". The original power state is
displayed after the inventory is refreshed.
To start a failover:
On the chassis Overview page, click More Actions > Failover.
A message is displayed stating that the system cannot be accessed during a failover.
Troubleshooting in chassis
The Troubleshoot option on the OME–Modular home page enables you to use the following options to resolve issues that occur
in the chassis:
● Extract Log—Use this option to extract application logs and save them to the NFS or CIFS locations on the network.
● Diagnostic Commands—Use this option to run diagnostic commands and parameters to troubleshoot the chassis network.
● Reset Management Module—Use this option to reboot the management module (MM) in a single management module
configuration, and perform a failover in a dual MM configuration.
NOTE:
During a factory reset process, the synchronization takes about 3-5 minutes. During this period, the serial, KVM,
and Quick Sync interfaces do not accept the factory password and the login attempt fails.
● Terminate Serial Connection—Use this option to end the existing serial sessions.
Blinking LEDs
You can use the Blink LED option on the OME–Modular home page to turn off or turn on the chassis LED.
Interfaces to access OME-Modular
After configuring the network settings in OME–Modular, you can remotely access OME-Modular using various interfaces. The
following table lists the interfaces that you can use to remotely access OME–Modular.
24
Logging in to OME-Modular