Release Notes
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition for PowerEdge MX7000 Chassis Release Notes
- Contents
- Release summary
- Compatibility
- New and enhanced features
- Fixes
- Important Notes
- Known issues
- Advanced Filter option not working in Audit Logs
- iDRAC SSO does not work in OME-Modular
- Inconsistent behavior in lead and member chassis sleds during slot deployment
- Configured local time not applied on lead chassis and member chassis after disabling NTP
- MAC identities displayed in RESERVED state
- Chassis alerts not received in Redfish event listener after management module failover task
- Redeployment of MCM profiles for all member chassis sleds fails when VLAN is modified in device-based deployment
- All member chassis passive module is getting rebooted when performing "racadm racreset" in lead chassis
- Maximum template deployment from OpenManage Enterprise on management module sleds causes management module chassis to be inaccessible
- Power supply input voltage and input current display nil for PSUs that are removed
- Windows keystroke does not work on sled when chassis is connected to KVM
- PSU type displays AC for removed PSU or empty PSU slot in DC chassis in SNMP and RESTful API interfaces
- Limitations
- Installation
- Resources and support
- Contacting Dell EMC
New and enhanced features
This release of OME-Modular supports:
● DC power
1.30.00
● Group configuration option on the Home page in multi chassis environment.
● Profiles menu to create, assign, edit, and redeploy profiles with identities separately from templates.
● Editing templates.
● Advanced license for:
○ Chassis telemetry for power, thermal, and fans
○ OpenID Connect Provider for delegated authentication
● Redfish alert forwarding. For more information, see the OpenManage Enterprise Modular Edition RESTful API Guide.
● Ethernet IOM switch replacement wizard for easy replacement of faulty fabric switches.
● L2 Multicast in SmartFabric Services.
● LCD enhancement using PIN entry to unlock emergency access to local actions such as chassis power off.
● Reminder to select backup chassis.
● Same SSO login session sharing in tabs and not counting against the limit on number of sessions.
● Fabric creation progress banner.
● OS10 DUP to be posted in the validated stack catalog.
● Link to Release Notes from the info icon on the Compliance Report page.
● Displaying pre-requisites and dependencies for components in compliance report.
● Automatic restoration of configuration to Right Control Panel (RCP) on replacement. For more information, see the Dell
EMC PowerEdge MX7000 Enclosure Field Service Manual.
● PowerEdge MX750c platform.
1.20.10
● Quad-Port Ethernet adapters in up to five MX7000 chassis in a scalable fabric.
● Up to 512 VLANs per fabric, 256 VLANs per server port, and up to 512 VLANs per uplink.
● The category, "Unknown" in compliance reports for components that are not supported in catalogs.
● Additional topologies for Fabric Expander Module connectivity.
1.20.00
● Deploying templates on empty slots or slots that compute sleds occupy.
● Reclaiming MAC identities after removing profiles that are associated with blade servers.
● Synchronizing VLAN definitions of OME-Modular and OpenManage Enterprise.
● Alert notifications when a chassis is onboarded.
● Configuring Forward Error Correction (FEC) for SmartFabric.
● Propagating VLANs without server reboot.
● Deploying operating system using Boot to ISO after applying profile.
● Enhancements to Uplink Failure Detection.
● Enabling racadm connect to Brocade MXG610s.
● Performing Hard Reset only on iDRAC instead of whole sled.
● Setting Name field as the default sort order in device grids.
● Enhanced alert pop-ups to appear on the upper right corner of the user interface.
3
8 New and enhanced features