Release Notes
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition for PowerEdge MX7000 Chassis Release Notes
- Contents
- Release summary
- Compatibility
- New and enhanced features
- Fixes
- Important Notes
- Known issues
- Advanced Filter option not working in Audit Logs
- iDRAC SSO does not work in OME-Modular
- Inconsistent behavior in lead and member chassis sleds during slot deployment
- Configured local time not applied on lead chassis and member chassis after disabling NTP
- MAC identities displayed in RESERVED state
- Chassis alerts not received in Redfish event listener after management module failover task
- Redeployment of MCM profiles for all member chassis sleds fails when VLAN is modified in device-based deployment
- All member chassis passive module is getting rebooted when performing "racadm racreset" in lead chassis
- Maximum template deployment from OpenManage Enterprise on management module sleds causes management module chassis to be inaccessible
- Power supply input voltage and input current display nil for PSUs that are removed
- Windows keystroke does not work on sled when chassis is connected to KVM
- PSU type displays AC for removed PSU or empty PSU slot in DC chassis in SNMP and RESTful API interfaces
- Limitations
- Installation
- Resources and support
- Contacting Dell EMC
All member chassis passive module is getting
rebooted when performing "racadm racreset" in lead
chassis
Description Standby management system modules on the Member chassis are rebooted after “racadm racreset”
operation is performed on Lead chassis.
Workaround
● If the system is already in failed state, a user can change the timezone to something other than GMT
from Lead MSM GUI/Standalone which propagates the new timezone to all the Members in the group.
Else, irrespective of MCM or Standalone setup, before performing “racadm racresetcfg”, set the time
zone to GMT.
● If the setup is already in MCM group, remove the member chassis from the group and change the
timezone as stated above before performing the “racadm racresetcfg”.
Systems affected All systems supported in this release
Tracking number 195686
Maximum template deployment from OpenManage
Enterprise on management module sleds causes
management module chassis to be inaccessible
Description
When maximum template (160 sleds) deployment is triggered from OpenManage Enterprise, OME-
Modular becomes unresponsive.
Workaround Deploy templates in smaller groups or wait for OpenManage Enterprise to complete the job and the
system recovers.
Systems affected All systems supported in this release
Tracking number 198313
Power supply input voltage and input current display
nil for PSUs that are removed
Description
When a Power Supply Unit (PSU) is removed from the chassis and an SSE get call is run using a browser,
the PSUInputVoltage and PSUInputCurrent display "Nil" for the PSU.
Workaround Remove the external power supply to prevent the issue.
Systems affected All systems supported in this release
Tracking number 201641
Windows keystroke does not work on sled when
chassis is connected to KVM
Description
The Windows key is not effective when you press it from the KVM session.
Workaround All keystrokes work correctly with Virtual Network Computing (VNC) and vConsole. You can switch to
vConsole or VNC.
Systems affected All systems supported in this release.