Release Notes
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition Version 1.00.10 for PowerEdge MX7000 Chassis Release Notes
- Release summary
- Compatibility
- New and enhanced features
- Fixes
- Bandwidth and port details
- Single Sign-On with CSR
- Storage sled and storage IOM updates
- Root password application
- FCoE virtual MAC addresses
- OME-Modular unresponsive
- HTTPS firmware catalog share
- Compute sled firmware updates in member chassis
- Compute sled updates
- Failure of compute sled updates in MCM
- FIPS enabled systems
- Deployment and configuration job
- Migrating profiles
- Firmware update failure
- Login failure
- OME-Modular version information for member chassis
- Failure of compute sled updates in MCM
- Firmware update job status
- Single management module connectivity
- Important Notes
- Known issues
- Unable to restore network configuration attributes
- Fault list does not contain HWC2131
- Chassis KVM output may be lost after AC power outage in chassis
- ISL Cabling Diagram not shown correctly in Microsoft Edge and Internet Explorer
- Unable to view details of template created from a reference device
- Firmware catalog may be deleted automatically after editing
- Error displayed when creating a local user account under certain conditions
- Cannot perform a graceful shut down of all compute sleds
- Check Compliance operation fails to run and no error message is displayed
- Unable to deploy chassis profile after removing syslog or SNMP destinations
- Unable to edit firmware catalog in specific scenarios
- Unable to restore iDRAC from the lead chassis
- Unable to export chassis profile using hostname or FQDN
- Request to join a group fails when using Microsoft Edge or Internet Explorer
- Devices may not appear after being moved from the lead chassis to a member chassis
- Set Proxy operation fails when using a hostname ending with a numeric character
- Using special characters while setting iDRAC password causes error
- Descriptive error not displayed when compute sled is in lockdown mode and VLAN settings are changed
- Last run date for some jobs may be displayed incorrectly after firmware update
- Unable to start MM Update when IOMs or storage components are selected as chassis components while updating firmware from baselines
- IOM firmware updates fail intermittently when IOMs are selected as part of chassis component while updating firmware from baselines
- Multiple Firmware Update jobs start for IOMs or storage devices when IOMs or storage devices are selected while updating firmware from baselines
- OME - Modular slows down while deploying many compute sleds in 20 chassis setup
- PowerEdge MX 10GbT PTM is not displayed on chassis Group Topology page
- MCM Lead chassis does not display alerts from chassis components
- Bandwidth settings are not deployed on IOMs in fabric mode when an imported template is used
- Alerts are not received through SYSLOG, SNMP, or EMAIL after downgrading OME-Modular firmware
- Limitations
- Installation
- Resources and support
- Contacting Dell EMC
message is not displayed on the Chassis Fault List on the dashboard. This issue can occur during the
management module firmware update.
Workaround If the hardware log message HWC2131 was generated during a management module firmware update,
ignore the message.
Systems affected PowerEdge MX7000
Tracking number 108458
Chassis KVM output may be lost after AC power
outage in chassis
Description If the compute sleds have NVDIMMs and if AC power is lost while the NVDIMM is in read or write mode,
the KVM output may not be restored when the AC power is restored.
Workaround Reset the management module twice or perform failover on the management module twice using OME–
Modular web interface or RACADM. To perform a reset using the OME–Modular web interface, go to
Home > Troubleshoot > Reset Management Module.
Systems affected PowerEdge MX7000
Tracking number 108499
ISL Cabling Diagram not shown correctly in Microsoft
Edge and Internet Explorer
Description
During fabric creation, a diagram of the selected Fabric Design is displayed. The diagram indicates the
type of IOMs used and ISL cabling between them. Internet Explorer and Edge do not display these
diagrams correctly and may display black shapes instead of the correct ISL cabling.
Workaround Use Chrome or Firefox. If you cannot use either of these browsers, the fabric creation workflow provides
a printable summary of the defined fabric that you can use to view the image correctly.
Systems affected MX9116n, MX7116n
Tracking number 107300
Unable to view details of template created from a
reference device
Description
If you create a template using a reference device and that device is then removed from the chassis, you
cannot view all the attributes captured in that template through the OME–Modular web interface. The
template can still be deployed or used normally.
Workaround To view the template attributes on the web interface, wait for the chassis inventory to be refreshed. The
inventory is refreshed automatically every 30 minutes. You can also manually refresh the inventory using
the OME–Modular web interface.
Systems affected PowerEdge MX7000, PowerEdge MX740c, PowerEdge MX840c
Tracking number 107891