Release Notes

Table Of Contents
message is not displayed on the Chassis Fault List on the dashboard. This issue can occur during the
management module firmware update.
Workaround If the hardware log message HWC2131 was generated during a management module firmware update,
ignore the message.
Systems affected PowerEdge MX7000
Tracking number 108458
Chassis KVM output may be lost after AC power
outage in chassis
Description If the compute sleds have NVDIMMs and if AC power is lost while the NVDIMM is in read or write mode,
the KVM output may not be restored when the AC power is restored.
Workaround Reset the management module twice or perform failover on the management module twice using OME
Modular web interface or RACADM. To perform a reset using the OMEModular web interface, go to
Home > Troubleshoot > Reset Management Module.
Systems affected PowerEdge MX7000
Tracking number 108499
ISL Cabling Diagram not shown correctly in Microsoft
Edge and Internet Explorer
Description
During fabric creation, a diagram of the selected Fabric Design is displayed. The diagram indicates the
type of IOMs used and ISL cabling between them. Internet Explorer and Edge do not display these
diagrams correctly and may display black shapes instead of the correct ISL cabling.
Workaround Use Chrome or Firefox. If you cannot use either of these browsers, the fabric creation workflow provides
a printable summary of the defined fabric that you can use to view the image correctly.
Systems affected MX9116n, MX7116n
Tracking number 107300
Unable to view details of template created from a
reference device
Description
If you create a template using a reference device and that device is then removed from the chassis, you
cannot view all the attributes captured in that template through the OMEModular web interface. The
template can still be deployed or used normally.
Workaround To view the template attributes on the web interface, wait for the chassis inventory to be refreshed. The
inventory is refreshed automatically every 30 minutes. You can also manually refresh the inventory using
the OMEModular web interface.
Systems affected PowerEdge MX7000, PowerEdge MX740c, PowerEdge MX840c
Tracking number 107891