Release Notes

Table Of Contents
Known issues
Topics:
Unable to restore network configuration attributes
Fault list does not contain HWC2131
Chassis KVM output may be lost after AC power outage in chassis
ISL Cabling Diagram not shown correctly in Microsoft Edge and Internet Explorer
Unable to view details of template created from a reference device
Firmware catalog may be deleted automatically after editing
Error displayed when creating a local user account under certain conditions
Cannot perform a graceful shut down of all compute sleds
Check Compliance operation fails to run and no error message is displayed
Unable to deploy chassis profile after removing syslog or SNMP destinations
Unable to edit firmware catalog in specific scenarios
Unable to restore iDRAC from the lead chassis
Unable to export chassis profile using hostname or FQDN
Request to join a group fails when using Microsoft Edge or Internet Explorer
Devices may not appear after being moved from the lead chassis to a member chassis
Set Proxy operation fails when using a hostname ending with a numeric character
Using special characters while setting iDRAC password causes error
Descriptive error not displayed when compute sled is in lockdown mode and VLAN settings are changed
Last run date for some jobs may be displayed incorrectly after firmware update
Unable to start MM Update when IOMs or storage components are selected as chassis components while updating
firmware from baselines
IOM firmware updates fail intermittently when IOMs are selected as part of chassis component while updating firmware
from baselines
Multiple Firmware Update jobs start for IOMs or storage devices when IOMs or storage devices are selected while updating
firmware from baselines
OME - Modular slows down while deploying many compute sleds in 20 chassis setup
PowerEdge MX 10GbT PTM is not displayed on chassis Group Topology page
MCM Lead chassis does not display alerts from chassis components
Bandwidth settings are not deployed on IOMs in fabric mode when an imported template is used
Alerts are not received through SYSLOG, SNMP, or EMAIL after downgrading OME-Modular firmware
Unable to restore network configuration attributes
Description
The restore operation does not restore the network configuration attributesNetwork Auto
Negotiation, Network Speed, and Duplex Mode.
Workaround Log in to OMEModular, go to Chassis Settings > Network and configure the network settings
Network Auto Negotiation, Network Speed, and Duplex Mode.
Systems affected All system supported by this release.
Tracking number 107884
Fault list does not contain HWC2131
Description
The hardware log contains the entry HWC2131 "The Management Module cannot communicate
with the right control panel because of internal issues". However, this error
6
Known issues 13