Release Notes
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition Version 1.00.10 for PowerEdge MX7000 Chassis Release Notes
- Release summary
- Compatibility
- New and enhanced features
- Fixes
- Bandwidth and port details
- Single Sign-On with CSR
- Storage sled and storage IOM updates
- Root password application
- FCoE virtual MAC addresses
- OME-Modular unresponsive
- HTTPS firmware catalog share
- Compute sled firmware updates in member chassis
- Compute sled updates
- Failure of compute sled updates in MCM
- FIPS enabled systems
- Deployment and configuration job
- Migrating profiles
- Firmware update failure
- Login failure
- OME-Modular version information for member chassis
- Failure of compute sled updates in MCM
- Firmware update job status
- Single management module connectivity
- Important Notes
- Known issues
- Unable to restore network configuration attributes
- Fault list does not contain HWC2131
- Chassis KVM output may be lost after AC power outage in chassis
- ISL Cabling Diagram not shown correctly in Microsoft Edge and Internet Explorer
- Unable to view details of template created from a reference device
- Firmware catalog may be deleted automatically after editing
- Error displayed when creating a local user account under certain conditions
- Cannot perform a graceful shut down of all compute sleds
- Check Compliance operation fails to run and no error message is displayed
- Unable to deploy chassis profile after removing syslog or SNMP destinations
- Unable to edit firmware catalog in specific scenarios
- Unable to restore iDRAC from the lead chassis
- Unable to export chassis profile using hostname or FQDN
- Request to join a group fails when using Microsoft Edge or Internet Explorer
- Devices may not appear after being moved from the lead chassis to a member chassis
- Set Proxy operation fails when using a hostname ending with a numeric character
- Using special characters while setting iDRAC password causes error
- Descriptive error not displayed when compute sled is in lockdown mode and VLAN settings are changed
- Last run date for some jobs may be displayed incorrectly after firmware update
- Unable to start MM Update when IOMs or storage components are selected as chassis components while updating firmware from baselines
- IOM firmware updates fail intermittently when IOMs are selected as part of chassis component while updating firmware from baselines
- Multiple Firmware Update jobs start for IOMs or storage devices when IOMs or storage devices are selected while updating firmware from baselines
- OME - Modular slows down while deploying many compute sleds in 20 chassis setup
- PowerEdge MX 10GbT PTM is not displayed on chassis Group Topology page
- MCM Lead chassis does not display alerts from chassis components
- Bandwidth settings are not deployed on IOMs in fabric mode when an imported template is used
- Alerts are not received through SYSLOG, SNMP, or EMAIL after downgrading OME-Modular firmware
- Limitations
- Installation
- Resources and support
- Contacting Dell EMC
FIPS enabled systems
Fixed an issue on FIPS enabled systems to send emails as part of an alert policy, when SMTP settings are configured with SSL
enabled.
Tracking number
109796
Deployment and configuration job
Fixed an issue that was causing the deployment and configuration job to not start for newly inserted servers when Quick Deploy
was configured for all chassis slots.
Tracking number
109724
Migrating profiles
Fixed an issue where migrating profiles was not possible after detaching the profile from the slot where the server was inserted.
Tracking number
109879
Firmware update failure
Fixed an issue that was causing failure of firmware update using a catalog that is accessed through an NFS share, after
upgrading OME - Modular to version 1.00.01 from 1.00.00.
Tracking number
110116
Login failure
Fixed an issue where logging into the chassis using SSH, Serial, and KVM was failing when the password contained certain
special characters.
Tracking number
110160
OME-Modular version information for member chassis
Fixed an issue that was causing the lead chassis in MCM to display incorrect OME-Modular version information for the member
chassis in domain-related REST APIs. The incorrect information was displayed when the OME-Modular version in the member
chassis was upgraded to the latest version.
Tracking number
109587
Failure of compute sled updates in MCM
Fixed an issue that was causing failure of updates of some compute sleds in MCM.
Tracking number
10