Users Guide

Table Of Contents
Viewing chassis hardware logs
The logs of activities performed on the hardware components associated with the chassis are displayed on the OMEModular
Hardware Logs page. The log details that are displayed include severity, message ID, category, timestamp, and description. You
can also view the chassis hardware logs by clicking Devices > Chassis > View Details > Hardware Logs.
You can perform the following tasks on the Hardware Logs page:
Click Advanced Filter to filter the logs based on severity, message ID, start date, end date, or category.
Click Export > Export Current Page to export all the displayed logs.
Select a specific log and click Export.
NOTE: If a racrestcfg is performed, the message, "CMC8709 and CMC8710 logs are appearing 2 times each, one for
slot 1 and other for slot 2", is displayed on the Hardware Logs page.
Configuring OMEModular
The Application Settings menu on the home page enables you to configure various settings for OMEModular. The settings
include the following:
Network
Users
Security
Alerts
Viewing current configuration
Click Application Settings > Network > Current Settings.
The current network, IPv4, and IPv6 settings are displayed.
Configuring OMEModular IP address
1. Click Application Settings > Network > Address Configuration.
2. Ensure that the Enable NIC option is selected.
3. Enable the required IP version-IPv4 or IPv6.
NOTE:
The IOM and OMEModular must be registered in the DNS. Else, the message, "Warning: Unit file of
rsyslog.service changed on disk, 'systemctl daemon-reload' recommended.", is displayed.
NOTE: After rebooting OMEModular, the public interface with the OMEModular IP is available after 12 minutes
approximately.
4. Enable the DHCP option, and enter the IP address and other details.
Configuring OMEModular web server
1. Click Application Settings > Network > Web Server Configuration.
2. Ensure that the Enable Web Server option is selected.
3. Enter the timeout value in minutes.
4. Enter the port number for the web server.
You can enter a port number in the 10-65535 range. The default port number is 443.
When the web server https port settings from the lead chassis are applied to member chassis as part of the add or join
member task, refresh the inventory for the lead chassis manually to see the correct https port for the member chassis,
on the Hardware > Device Management Info page. Launch the member chassis from the lead chassis to see the port
number.
Logging in to OME-Modular
57