Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition for PowerEdge MX7000 Chassis User's Guide
- Contents
- Overview
- Updating firmware for PowerEdge MX solution
- MX7000 Solution Baselines
- Upgrading ethernet switch using DUP
- OME-Modular licenses
- Logging in to OME-Modular
- Logging in to OME–Modular as local, Active Directory, or LDAP user
- Logging in to OME-Modular using OpenID Connect
- OME-Modular home page
- Viewing device health
- Setting up chassis
- Initial configuration
- Configuring chassis settings
- Managing chassis
- Chassis groups
- Controlling chassis power
- Backing up chassis
- Restoring chassis
- Exporting chassis profiles
- Managing chassis failover
- Troubleshooting in chassis
- Blinking LEDs
- Interfaces to access OME-Modular
- Viewing chassis hardware
- Viewing chassis alerts
- Viewing chassis hardware logs
- Configuring OME–Modular
- Viewing current configuration
- Configuring users and user settings
- Configuring login security settings
- Configuring alerts
- Managing compute sleds
- Managing Profiles
- Managing storage
- Managing templates
- Managing identity pools
- Ethernet IO Modules
- MX Scalable Fabric architecture
- SmartFabric Services
- Managing networks
- Managing Fibre Channel IOMs
- Managing firmware
- Monitoring alerts and logs
- Monitoring audit logs
- Use case scenarios
- Troubleshooting
- Storage
- Firmware update is failing
- Storage assignment is failing
- SAS IOM status is downgraded
- SAS IOM health is downgraded
- Drives on compute sled are not visible
- Storage configuration cannot be applied to SAS IOMs
- Drives in OpenManage are not visible
- iDRAC and OpenManage drive information do not match
- The assignment mode of storage sled is unknown
- Unable to access OME-Modular using Chassis Direct
- Troubleshooting lead chassis failure
- Storage
- Recommended slot configurations for IOMs
- Upgrading networking switch using different OS10 DUP versions
- Upgrading networking switch using CLI
9. Enter a name for the catalog, select the catalog source, and click Finish to save the changes and return to the Chassis
Deployment Wizard.
10. Click Next to view the Proxy tab and configure the proxy settings.
OME–Modular uses the proxy settings to access the Dell EMC website for the latest catalogs. You can also enable the
HTTPS proxy settings and proxy authentication.
11. Click Next to view the Group Definition tab.
12. Select Create Group to configure the chassis group settings.
13. Click Next to view the Summary tab.
NOTE: After setting the time in the lead chassis, wait for the lead chassis time and the member chassis time to
synchronize before performing any operation. The time configuration can be disruptive.
Configuring chassis settings
You can configure the following settings for a chassis:
● Power
● Network
● Network Services
● Local Access Configuration
● Location
● Quick Deploy
Configure chassis power
To configure the chassis power settings:
1. Click Devices > Chassis > View Details > Settings > Power.
The Power configuration section is expanded.
2. Select Enable Power Cap to specify the maximum power consumption capacity for the chassis. The Power Cap limits the
power consumption of the chassis. When the power cap is reached, the sleds are throttled based on their power priority. You
can specify the capacity in Watts, BTU/h, or percentage. The Power Cap option is displayed only if the Enable Power Cap
check box is selected. The recommended power cap is 0-32767 Watts or 0-100 %. If you change the power cap in BTU/h,
the power cap in W also changes.
MX7000 chassis supports power sources of 110 and 220 Volts.
3. In the Redundancy Configuration section, select the required redundancy policy.
Power redundancy policies facilitate management of power consumption and power failure tolerance in the chassis. The
available options are:
● No Redundancy—This policy distributes the enclosure power load across all PSUs. There are not any specific PSU
population requirements for No Redundancy. The intent of the No Redundancy policy is to have the highest possible
limit for power enablement of devices that are added to the enclosure. If there are single or multiple PSU failures, then
the enclosure limits the performance to operate within the power capabilities of the remaining PSUs.
● Grid Redundancy—This policy distributes the enclosure power load across all PSUs. The six PSUs are organized into
two groups: Grid A consists of PSUs 1, 2, 3, and Grid B consists of PSUs 4, 5, 6. It is recommended that the PSUs
are populated in the following order: 1, 4, 2, 5, 3, 6, where an equal number of PSUs on each grid is optimized for Grid
Redundancy. The grid with the largest PSU capacity determines the limit for power enablement of devices that are added
to the enclosure. If there is a grid or PSU failure, then the enclosure power is distributed among the remaining PSUs with
the intent that a single healthy grid continues to provide power to the system without degrading the performance.
● PSU Redundancy—This policy distributes the enclosure power load across all PSUs. There are no specific PSU
population requirements for redundant PSUs. PSU redundancy is optimized for a population of six PSUs, and the
enclosure limits the power enablement of devices to fit within five PSUs. If there is a single PSU failure, then the
enclosure power is distributed among the remaining PSUs without degrading the performance. If there are less than six
PSUs, then the enclosure limits the power enablement of devices to fit within all populated PSUs. If there is a single PSU
failure, then the enclosure limits the performance to operate within the power capabilities of the remaining PSUs.
4. In the Hot Spare Configuration section, select the Enable Hot Spare to configure the Hot Spare primary grid.
The Hot Spare feature facilitates voltage regulation when power utilization by Power Supply Unit (PSUs) is low, considering
the total output capacity of the PSU. By default, the Hot Spare is enabled. When the Hot Spare is enabled, a redundant PSU
is put in sleep state when the power utilization is low. The Hot Spare is not enabled if the:
36