Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition for PowerEdge MX7000 Chassis User's Guide
- Contents
- Overview
- Updating firmware for PowerEdge MX solution
- MX7000 Solution Baselines
- Upgrading ethernet switch using DUP
- OME-Modular licenses
- Logging in to OME-Modular
- Logging in to OME–Modular as local, Active Directory, or LDAP user
- Logging in to OME-Modular using OpenID Connect
- OME-Modular home page
- Viewing device health
- Setting up chassis
- Initial configuration
- Configuring chassis settings
- Managing chassis
- Chassis groups
- Controlling chassis power
- Backing up chassis
- Restoring chassis
- Exporting chassis profiles
- Managing chassis failover
- Troubleshooting in chassis
- Blinking LEDs
- Interfaces to access OME-Modular
- Viewing chassis hardware
- Viewing chassis alerts
- Viewing chassis hardware logs
- Configuring OME–Modular
- Viewing current configuration
- Configuring users and user settings
- Configuring login security settings
- Configuring alerts
- Managing compute sleds
- Managing Profiles
- Managing storage
- Managing templates
- Managing identity pools
- Ethernet IO Modules
- MX Scalable Fabric architecture
- SmartFabric Services
- Managing networks
- Managing Fibre Channel IOMs
- Managing firmware
- Monitoring alerts and logs
- Monitoring audit logs
- Use case scenarios
- Troubleshooting
- Storage
- Firmware update is failing
- Storage assignment is failing
- SAS IOM status is downgraded
- SAS IOM health is downgraded
- Drives on compute sled are not visible
- Storage configuration cannot be applied to SAS IOMs
- Drives in OpenManage are not visible
- iDRAC and OpenManage drive information do not match
- The assignment mode of storage sled is unknown
- Unable to access OME-Modular using Chassis Direct
- Troubleshooting lead chassis failure
- Storage
- Recommended slot configurations for IOMs
- Upgrading networking switch using different OS10 DUP versions
- Upgrading networking switch using CLI
NOTE: During firmware update, when the active MM reboots and the standby MM is active, some messages on
the Execution Details page for the firmware update are not displayed. The messages are not displayed owing to
synchronization issues.
NOTE: During the OME–Modular firmware update, multiple users can upload the OME–Modular DUP using any
interface. However, a warning message may be displayed after the firmware update job is initiated.
NOTE: For nondefault VLAN, the management IPv6 IP of MX9116n or MX5108n IOMs is unreachable if, the DHCP V6
configuration in ToR switch does not have the IPV6 default gateway.
The number of IOMs that can be updated differs based on the IOM versions. The following table displays the number of
IOMs that can be updated at a time.
Table 23. IOM Firmware update matrix
IOM Version OME-M Version No. of IOMs
10.5.0.5 1.10.20 or later 4
10.5.0.7 1.20.00 or later 6
10.5.1.6 1.20.10 or later 6
10.5.2.3 1.30.00 and later No restrictions
You must group the IOMs for firmware update depending on the type of IOM. The following table displays an example of
grouping 12 IOMs for firmware update.
Table 24. Grouping IOMs for firmware update
Example of 12 IOMs Combination Group 1 Group 2 Group 3
10.5.0.5 6 Fabrics Fabric 1-2 Fabric 3-4 Fabric 5-6
12 Full switch IOM 1-4 IOM 5-8 IOM 9-12
4 fabrics and 4 Full
switch
Fabric 1-2 Fabric 3-4 4 Full switch IOM
10.5.0.7 or 10.5.1.6 6 Fabrics Fabric 1-3 Fabric 4-6 Not Applicable
12 Full switch IOM 1-6 IOM 6-12 Not Applicable
4 fabrics and 4 Full
switch
Fabric 1-3 Fabric 4 and 4 full
switch IOM
Not Applicable
Once all IOMs are updated to 10.5.2.4 stack, network IOMs display two software components for update. The available
options are:
● Dell EMC Networking SmartFabric OS10
● Dell EMC Networking ONIE Firmware
Limitations for ONIE firmware update are:
● ONIE firmware update option is available only if the OS10 version is 10.5.2.3 or later.
● When you select the network IOM that is part of a fabric for ONIE update, other nodes in the fabric are updated
automatically.
● If you insert an old version of IOM, the ONIE firmware cannot be updated before updating OS10 to 10.5.2.4 version.
NOTE:
ONIE component firmware is not updated due to the issue of system not booting into ONIE, when GRUB menu is
displayed with serial control character. This issue is addressed in 3.35.1.1-15 ONIE firmware version. If ONIE update fails
or encounters ONIE booting issue, retry the ONIE component firmware update.
Managing firmware 117