CLI Guide
Table Of Contents
- Dell EMC OpenManage Enterprise Modular Edition for PowerEdge MX7000 Chassis RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM sub command details
- Guidelines to quote strings containing special characters when using RACADM commands
- Question mark and question mark with subcommand
- help and help with subcommand
- arp
- chassisaction
- chassisgroup
- chassislog
- cmcchangeover
- config
- connect
- deploy
- faultlist
- getconfig
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getsensorinfo
- getsysinfo
- ifconfig
- ping
- ping6
- racreset
- racresetcfg
- serveraction
- setniccfg
- swinventory
- traceroute
- traceroute6
- OpenManage Enterprise Modular property database group and object descriptions
PWR 5 PS-5 Online
OK DC
PWR 6 PS-6 Online
OK DC
Example
racadm getsensorinfo -c
Sensor Type: Fan
<Num> <sensorName> <status> <reading> <LC> <UC>
1 Fan-1 Not OK N/A rpm N/A N/A
2 Fan-2 OK 17174 rpm N/A N/A
3 Fan-3 OK 17238 rpm N/A N/A
4 Fan-4 OK 17081 rpm N/A N/A
5 Fan-5 OK 14499 rpm N/A N/A
6 Fan-6 Not OK N/A rpm N/A N/A
7 Fan-7 OK 14502 rpm N/A N/A
8 Fan-8 OK 14505 rpm N/A N/A
9 Fan-9 OK 14479 rpm N/A N/A
Sensor Type: Temp
<Num> <sensorName> <status> <reading> <LC> <UC>
<LW> <UW>
1 Chassis Inlet Temperature OK 29 C -7 47
3 43
2 Sled 2 Inlet Temperature OK 24 C -7 47
3 43
3 Sled 3 Inlet Temperature OK 25 C -7 42
3 38
4 Sled 4 Inlet Temperature OK 25 C -7 47
3 43
5 Sled 5 Inlet Temperature OK 26 C -7 47
3 43
6 Sled 6 Inlet Temperature OK 26 C -7 42
3 38
7 Sled 7 Inlet Temperature OK 26 C -7 47
3 43
Sensor Type: Power
<Num> <sensorName> <status> <health> <Power
Supply type>
1 PS-1 Slot Empty N/A AC
2 PS-2 Online OK AC
3 PS-3 Slot Empty N/A AC
4 PS-4 Online OK AC
5 PS-5 Configuration Error Not OK AC
6 PS-6 Input Lost Not OK AC
getsysinfo
Description
Displays general RAC and system information.
Synopsis
racadm getsysinfo [-d] [-c] [-4] [-6]
Input
● -d—Displays MM information
● -c—Displays chassis information
● -4—Displays IPv4 settings
● -6—Displays IPv6 settings
● -6 without -s option—Sets the static IPv6 address for the chassis
● -6 without -d option—Enables autoconfiguration of IPv6 for the chassis
RACADM sub command details 25