CLI Guide

Display status of fan module 3 in the chassis.
racadm getmodinfo -m fan-3
getniccfg
Description Displays the network settings for modules.
Synopsis
racadm getniccfg [-m <module>]
Input -mThe <module> must be one of the following values:
chassisDefault state if -m is not specified.
switch-<n>Where n = 16
Example
Display switch network settings
racadm getniccfg -m switch-1
Display chassis network settings
racadm getniccfg -m chassis
getpbinfo
Description
Gets power budget status information. If there is no power supply to the PSU, the output of the
command is displayed as Input Lost. If there is a mismatch in the power source, for example, a PSU
of 220 Volts and PSU of 110 Volts are combined, then the output of the command is displayed as
Configuration Error.
Synopsis
racadm getpbinfo
Input
racadm getpbinfo
Example -
chassis with AC
power supply
type
[Power Budget Status]
System Input Power = 615 W (2098 BTU/h)
Peak System Power = 628 W (2142 BTU/h)
Peak System Power Timestamp = 11:37:36 08/08/2018
Minimum System Power = 606 W (2067 BTU/h)
Minimum System Power Timestamp = 10:16:08 08/06/2018
Overall Power Health = Not OK
Redundancy = No
System Input Power Cap = Disabled
Redundancy Policy = None
Dynamic PSU Engagement Enabled = Not Applicable
System Input Max Power Capacity = 11571 W
Input Redundancy Reserve = Not Applicable
Input Power Allocated to Servers = Not Applicable
Input Power Allocated to Chassis Infrastructure = Not Applicable
Total Input Power Available for Allocation = 2385 W (8137 BTU/h)
Standby Input Power Capacity = Not Applicable
Server Based Power Management Mode = Not Applicable
Max Power Conservation Mode = Not Applicable
Server Performance Over Power Redundancy = Not Applicable
Power Available for Server Power-on = Not Applicable
Extended Power Performance(EPP) Status = Not Applicable
Available Power in EPP Pool = Not Applicable
20 RACADM sub command details