CLI Guide
Table Of Contents
- Dell EMC OpenManage Enterprise Modular Edition Version 1.00.10 for PowerEdge MX7000 Chassis RACADM Command Line Reference Guide
- Introduction
- RACADM sub command details
- Guidelines to quote strings containing special characters when using RACADM commands
- Question mark and question mark with subcommand
- help and help with subcommand
- arp
- chassisaction
- chassisgroup
- chassislog
- cmcchangeover
- config
- connect
- deploy
- faultlist
- getconfig
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getsensorinfo
- getsysinfo
- ifconfig
- ping
- ping6
- racreset
- racresetcfg
- serveraction
- setniccfg
- swinventory
- traceroute
- traceroute6
- OME Modular property database group and object descriptions
This property is used only if cfgNicUseDhcp is set to 1(true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are
set to 1(true).
The management module can obtain its DNS domain name from either a DHCP or DHCPv6 server, if all of the following
properties are set to 1 (true):
● cfgNicIPv4Enable
● cfgNicUseDhcp
● cfgIPv6Enable
● cfgIPv6AutoConfig
● cfgDNSDomainNameFromDHCP
● cfgDNSDomainName (Read or Write)
The network administrator must make sure that these DHCP servers are configured to provide the same DNS domain name to
the management module, otherwise the domain name becomes unpredictable.
cfgStorageModule
Description This command is used only with the getconfig command.
Synopsis
Input
●
cfgStorageModuleStorageMode=<storage mode>
●
# cfgStorageModuleServiceTag=<service tag>
●
cfgStorageModuleAssetTag=
●
cfgConnectedSlots=<connected slots>
Example
● cfgStorageModuleStorageMode=2
●
# cfgStorageModuleServiceTag=MX0000
● cfgStorageModuleAssetTag=
●
cfgConnectedSlots=2,2,2,2,2,2,2,2
cfgStorageModuleStorageMode
Description
Displays the storage module.
Synopsis
cfgStorageModuleStorageMode=<storage mode>
Input
cfgStorageModuleStorageMode=<storage mode>
NOTE:
● If the storage mode is 1, then cfgConnectedSlots will be list of all connected slots to that
particular enclosure.
● If the storage mode is 2, then cfgConnectedSlots shows the assignment for each drive.
Example
cfgStorageModuleStorageMode=2
OME Modular property database group and object descriptions 27