The IPv6 Address, Prefix Length, and Gateway options are enabled only if the Enable Autoconfiguration check box is
cleared.
NOTE: For tagged or untagged VLAN network, any IPv6 setting configured using OME - Modular may not have the
default gateway. To get the default gateway, go to the respective OS10 CLI and enable Stateless Address
Autoconfiguration (SLAAC) on the respective tagged or untagged VLAN.
7. In the DNS Server Settings section, enter the Preferred DNS Server, Alternate DNS Server 1, and Alternate DNS
Server 2 addresses.
For MXG610s IOMs, you can set the Preferred DNS and Alternate Server 1 and 2 addresses. However, the server address for
Alternate DNS Server 2 is not applied though the response is successful as, MXG610s IOMs support only two server
address for DNS settings.
8. In the Management VLAN section, select Enable VLAN and enter the VLAN ID.
For MXG610s FC IOMs, DHCP works only without VLAN while Static IP works with or without VLAN configuration. To
change the IP configuration from DHCP IP to Static IP, perform the following steps:
a. Disable DHCP, configure the static IP, and save the configuration.
b. Enable VLAN, configure the VLAN ID, and save the configuration.
Configuring root password
To configure the root password:
1. Click All Devices > I/O Modules > View Details > Settings > Management or Devices > I/O Modules > View Details >
Settings > Management.
The I/O Modules page is displayed.
2. Enter the Host Name and Root Password for the IOM.
Configuring SNMP settings
To configure the SNMP settings:
1. Click All Devices > I/O Modules > View Details > Settings > Monitoring or Devices > I/O Modules > View Details >
Settings > Monitoring.
2. Select Enable SNMP to configure the SNMP version and community string.
Configuring advanced settings
To configure the advanced IOM settings:
1. Click All Devices > I/O Modules > View Details > Settings > Advanced or Devices > I/O Modules > View Details >
Settings > Advanced.
2. Select the options to replicate the chassis time and alert settings to the IOM.
Configuring ports
You can configure breakout, admin status, and MTUs for IOMs. You can configure breakout only for port groups.
NOTE: The port description is applicable only to full-switch mode IOMs. Update the port description in the IOM CLI.
NOTE: Ensure that the peer FC port has a fixed speed and matches the speed of the IOM FC port for the link to come up.
To configure breakout:
1. Click Devices > I/O Modules > View Details > Hardware > Port Information.
2. Select the port group and click Configure Breakout.
The Configure Breakout window is displayed.
3. Select the Breakout Type.
Ethernet IO Modules