Users Guide
○ Edit server profiles—You can edit the profile characteristics that are unique to the device or slot. If a profile is attached
to a compute, the updated profile configuration is propagated to the compute.
○ Remove slot associations—You can detach the server profile from the slot.
NOTE: When a compute sled is inserted into a chassis, sometimes the message, "No device image found", is displayed. To
resolve the issue refresh the inventory of the compute sled, manually.
Configuring compute settings
You can configure the following compute settings:
● Network
● Management
Configuring compute network settings
To configure the compute network settings:
1. Click Devices > Compute > View Details > Settings > Network.
2. In the General Settings section, select the LAN Enablement check box to configure the network settings.
3. Configure the IPv4, IPv6, and management VLAN settings.
Configuring compute management settings
To configure the compute management settings:
1. Click Devices > Compute > View Details > Settings > Management.
2. Configure the password to access the iDRAC console and select IPMI over LAN to enable access from OME–Modular to
iDRAC, through BIOS.
Viewing compute hardware
You can view the details of the hardware components that are installed in the compute sled, on the compute Hardware page.
The hardware components include processor, storage controller, and FRU.
NOTE:
If the storage controller cards are absent in iDRAC, the storage enclsoure details are not displayed on the Compute
> View Details > Hardware > Storage Enclosure page.
Viewing compute firmware
You can view the firmware list for the compute in the compute Firmware page. Click Devices > Compute > View Details >
Firmware.
The details include name of the device or component, impact assessment, current version, and baseline version.
You can perform the following tasks on the Firmware page:
● Update the existing firmware on the compute using Update Firmware.
● Downgrade the updated firmware version to the previous version using Rollback Firmware.
● Export the firmware baseline report in a .csv format using Export.
Viewing compute hardware logs
The logs of activities performed on the hardware components associated with the compute sled are displayed on the compute
Hardware Logs page. The log details that are displayed include severity, message ID, category, timestamp, and description.
To view the hardware logs, click Devices > Compute > View Details > Hardware Logs.
Managing compute sleds