Users Guide

Restoring chassis
You can restore the configuration of a chassis using a back up file, if the backed-up configuration is of the same chassis. You
must have the chassis administrator role with device configuration privilege to restore the chassis.
To restore a chassis:
1. On the chassis Overview page, click More Actions > Restore.
The Restore Chassis window is displayed.
2. Under Restore File Location, select the Share Type where the configuration backup file is located.
3. Enter the Network Share Address, and Network Share Filepath where the backup file is stored.
4. Enter the name of the Backup File.
5. If the Share Type is CIFS, enter the Domain, Username, and Password to access shared location. Else, go to step 6.
6. In the Restore File Password section, enter the Encryption Password to open the encrypted back up file.
7. Click Restore to restore the chassis.
A message is displayed indicating that the chassis is successfully restored.
You can check the status and details of the restore process on the Montitoring > Jobs page.
Exporting chassis profiles
You can export chassis profiles for cloning the settings to other chassis.
To export the chassis profile:
1. On the OMEModular home page, click More Actions > Export Profile.
The Export Profile window is displayed.
2. Select the Share Type.
3. Enter the network share address and path.
4. If the Share Type is CIFS, enter the Domain, User Name, and Password to access the shared location.
5. Click Export.
Managing chassis failover
Failover is applicable in dual management module configuration and is the process of transferring the active role to the standby
management module. Reboot the active management module and re-initialize the stand-by management module to assume the
active role. The failover operation takes up to 10 minutes for completion. OMEModular is unavailable during this process. You
must have the chassis administrator privilege to start a failover.
NOTE: After a failover, the chassis management performance returns to normal in a few minutes.
NOTE: During a failover, the chassis power state on the OMEModular GUI is displayed as "off". The original power state is
displayed after the inventory is refreshed.
To start a failover:
On the chassis Overview page, click More Actions > Failover.
A message is displayed stating that the system cannot be accessed during a failover.
Troubleshooting in chassis
The Troubleshoot option on the OMEModular home page enables you to use the following options to resolve issues that occur
in the chassis:
Extract LogUse this option to extract application logs and save them to the NFS or CIFS locations on the network.
Diagnostic CommandsUse this option to run diagnostic commands and parameters to troubleshoot the chassis network.
Reset Management ModuleUse this option to reboot the management module (MM) in a single management module
configuration, and perform a failover in a dual MM configuration.
24
Logging in to OME-Modular