Users Guide
Enter details of the network share, where the chassis profile is located and click Import.
3. In the Time Configuration tab, select the Configure Time Settings to configure the time zone and timestamp of the
configuration.
4. Select the Use NTP check box to configure the primary, secondary, or tertiary NTP addresses and click Next.
NOTE: It is recommended that at least three valid NTP servers, which synchronize to a single time source, are used to
ensure reliable synchronization.
If you select multiple NTP servers, OME–Modular selects the NTP server algorithmically.
The Activity and Alerts tab is displayed.
5. Configure the email, SNMP, and system log settings and click Next.
The iDRAC tab is displayed.
6. Select the Configure iDRAC Quick Deploy Settings check box to configure the password to access the iDRAC web
interface and the management IPs, and click Next.
You can select the slots to which the iDRAC Quick Deploy settings must be applied.
The Network IOM tab is displayed.
7. Select the Configure I/O Module Quick Deploy Settings check box to configure the password to access the IOM console
and management IPs, and click Next.
The Firmware tab is displayed.
8. Select the Configure all devices to use following catalog check box, select the network share type and click Catalog to
open the Add Firmware Catalog window.
9. Enter a name for the catalog, select the catalog source, and click Finish to save the changes and return to the Chassis
Deployment Wizard.
10. Click Next to view the Proxy tab and configure the proxy settings.
OME–Modular uses the proxy settings to access the Dell EMC website for the latest catalogs. You can also enable the HTTP
proxy settings and proxy authentication.
11. Click Next to view the Group Definition tab.
12. Select Create Group to configure the chassis group settings.
13. Click Next to view the Summary tab.
NOTE:
After setting the time in the lead chassis, wait for the lead chassis time and the member chassis time to
synchronize before performing any operation. The time configuration can be disruptive.
Configuring chassis settings
You can configure the following settings for a chassis:
● Power
● Network
● Network Services
● Local Access Configuration
● Location
● Quick Deploy
Configuring chassis power
To configure the chassis power settings:
1. Click Devices > Chassis > View Details > Settings > Power.
The Power configuration section is expanded.
2. Select Enable Power Cap to specify the maximum power consumption capacity for the chassis. You can specify the
capacity in Watts, BTU/h, or percentage.
MX7000 chassis supports power sources of 110 volts and 220 volts.
3. In the Redundancy Configuration section, select the required redundancy policy.
Power redundancy policies facilitate management of power consumption and power failure tolerance in the chassis. The
available options are:
Logging in to OME-Modular
15