CLI Guide
[System Power Policy Configuration]
System Input Power Cap = Disabled
Redundancy Policy = None
Dynamic PSU Engagement Enabled = Not Applicable
[Power Budgeting]
System Input Max Power Capacity = 11571 W
Input Redundancy Reserve = Not Applicable
Input Power Allocated to Servers = Not Applicable
Input Power Allocated to Chassis Infrastructure = Not Applicable
Total Input Power Available for Allocation = 2384 W (8134 BTU/h)
Standby Input Power Capacity = Not Applicable
getsensorinfo
Description Displays system sensors.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Input
racadm getsensorinfo
racadm getsensorinfo -c
where, -c—Compact output format
Example
● racadm getsensorinfo
<senType> <Num> <sensorName> <status>
<reading> <units> <LC> <UC> <PWM>
FanSpeed 1 Fan-1 Not OK N/
A rpm N/A N/A 0
FanSpeed 2 Fan-2 OK
17166 rpm N/A N/A 100
FanSpeed 3 Fan-3 OK
17250 rpm N/A N/A 100
FanSpeed 4 Fan-4 OK
17096 rpm N/A N/A 100
FanSpeed 5 Fan-5 OK
14513 rpm N/A N/A 100
FanSpeed 6 Fan-6 Not OK N/
A rpm N/A N/A 0
FanSpeed 7 Fan-7 OK
14510 rpm N/A N/A 100
FanSpeed 8 Fan-8 OK
14479 rpm N/A N/A 100
FanSpeed 9 Fan-9 OK
14484 rpm N/A N/A 100
<senType> <Num> <sensorName>
<status> <reading> <units> <LC> <UC>
Temp 1 Chassis Inlet Temperature
OK 27 Celsius -7 47
<senType> <Num> <sensorName> <status>
<health>
18
RACADM sub command details