CLI Guide

config
Description Modifies RAC configuration properties.
Synopsis
racadm config -g <group> -o <object> <value> [-m<module>]
racadm config -g <group> -i <index> -o <object> <value>
Input
-gConfiguration group to which the object belongs
-oConfiguration object to configure
-iIndex of indexed group, used with -g and -o
-mThe module must have one of the following values: - storage-<n>- where n=1 to 8.
NOTE: The storage -<n> option is available only for cfgStorageModule
<value>Value of the configuration object
Example
Configure a single property of a group:
racadm config -g cfgLanNetworking -o cfgDNSRacName NAME
Configure a single property of a group for a particular user:
racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPassword PASSWORD
connect
Description
Connects to blade serial console.
Synopsis
racadm connect [-b] -m <module>
Input
-bBinary mode
-mThe <module> option must be one of the following values:
server-<n>where n = 1 to 8
CAUTION: When executed from the OMEModular serial console, the connect -b option
stays connected until the management module resets or the serial console is terminated.
This connection is a potential security risk.
Example Connect to server 1 serial console:
racadm connect -m server-1
NOTE: Use quit key configured on the iDRAC to quit the console.
deploy
Description
Deploys blade or IOM by specifying required properties.
NOTE: The quick deploy command is not supported in RACADM.
12 RACADM sub command details