Users Guide
Table 25. Command description
Command Description
OS10# show image status View the current software download status.
e. Install the 10.5.0.5 software image in EXEC mode.
Table 26. Command description
Command Description
OS10# image install image-url
Example:
OS10# image install image://filename.bin
Install the software image.
f. (Optional) View the status of the current software install in EXEC mode.
Table 27. Command description
Command Description
OS10# show image status View the status of the current software install.
g. Change the next boot partition to the standby partition in EXEC mode. Use the active parameter to set the next boot
partition from standby to active.
Table 28. Command description
Command Description
OS10# boot system standby Change the next boot partition to standby.
h. (Optional) Check whether the next boot partition has changed to standby in EXEC mode.
Table 29. Command description
Command Description
OS10# show boot detail Check whether the next boot partition has changed.
i. Reload the new software image in EXEC mode.
Table 30. Command description
Command Description
OS10# reload Reload the new software.
j. After the installation is complete, enter the show version command to check if the latest version of the software that you
have installed is running in the system.
The example below shows that the 10.5.0.5 software is installed and running on the system.
OS10# show version
MX9116N-A2# show version
Dell EMC Networking OS10 Enterprise
Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved.
OS Version: 10.5.0.5
Build Version: 10.5.0.5.661
Build Time: 2020-02-15T00:45:32+0000
System Type: MX9116N-ON
Architecture: x86_64
Up Time: 1 day 20:37:53
MX9116N-A2#
2. Run the command, show smartfabric cluster member, in the Master networking switch. Confirm that the STATUS
of the upgraded switch is ONLINE in the command output, after it has reloaded. The networking switches with version
10.5.01 and higher uses SFS CLI, whereas the lower versions like 10.4.0E(R3S) and 10.4.0E(R4S) use python /opt/
dell/os10/bin/rest-service/tool/dnv_cli.py show cluster command. For steps to identify the master IOM,
see upgrading from versions earlier than 10.5.0.5 section.
Upgrading networking switch using CLI
125