CLI Guide

Not OK
PWR 6 PS-6 Slot Empty
N/A
racadm getsensorinfo -c
Sensor Type: Fan
<Num> <sensorName> <status> <reading> <LC> <UC>
1 Fan-1 Not OK N/A rpm N/A N/A
2 Fan-2 OK 17174 rpm N/A N/A
3 Fan-3 OK 17238 rpm N/A N/A
4 Fan-4 OK 17081 rpm N/A N/A
5 Fan-5 OK 14499 rpm N/A N/A
6 Fan-6 Not OK N/A rpm N/A N/A
7 Fan-7 OK 14502 rpm N/A N/A
8 Fan-8 OK 14505 rpm N/A N/A
9 Fan-9 OK 14479 rpm N/A N/A
Sensor Type: Temp
<Num> <sensorName> <status> <reading>
<LC> <UC>
1 Chassis Inlet Temperature OK 27 C
-7 47
Sensor Type: Power
<Num> <sensorName> <status> <health>
1 PS-1 Slot Empty N/A
2 PS-2 Online OK
3 PS-3 Slot Empty N/A
4 PS-4 Online OK
5 PS-5 Configuration Error Not OK
6 PS-6 Input Lost Not OK
getsysinfo
Description
Displays general RAC and system information.
Synopsis
racadm getsysinfo [-d] [-c] [-4] [-6]
Input
-dDisplays MM information
-cDisplays chassis information
-4Displays IPv4 settings
-6Displays IPv6 settings
-6 without -s optionSets the static IPv6 address for the chassis
-6 without -d optionEnables autoconfiguration of IPv6 for the chassis
Example
Displays Chassis Information
racadm getsysinfo -c
Displays MM Information
racadm getsysinfo -d
ifconfig
Description
Displays the network interface information.