CLI Guide

cmcchangeover
Description Changes the redundant state of the management module from active to standby and standby to active.
Synopsis
racadm cmcchangeover
Input racadm cmcchangeover
Example NA
NOTE: During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power state
is displayed after the inventory is refreshed.
config
Description Modifies the configuration properties of the management module.
Synopsis
racadm config -g <group> -o <object> <value> [-m <module>]
racadm config -g <group> -i <index> -o <object> <value>
Input
-gConfiguration group to which the object belongs
-oConfiguration object to configure
-iIndex of indexed group, which is used with -g and -o
-mThe module must have one of the following values: - storage-<n>- where n=1 to 8
NOTE: The storage -<n> option is available only for cfgStorageModule
<value>Value of the configuration object
Example
Configure a single property of a group:
racadm config -g cfgLanNetworking -o cfgDNSRacName NAME
Configure a single property of a group for a particular user:
racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPassword PASSWORD
connect
Description
Connects to switch or blade serial console. The connect command is supported only on firmware
interfaces.
Synopsis
racadm connect [-b] -m <module>
Input
-bBinary mode
If -b is used, reset OME-Modular to terminate the connect.
-mThe <module> option must be one of the following values:
server-<n>where n = 1-8
switch-<n>where n = 1-6
RACADM sub command details 13