Dell EMC OpenManage Enterprise Modular Edition Version 1.10.00 for PowerEdge MX7000 Chassis RACADM Command Line Reference Guide September 2019 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: Introduction................................................................................................................. 5 New in this release.............................................................................................................................................................. 5 Supported RACADM Interfaces.......................................................................................................................................
cfgDNSDomainName (Read or Write)................................................................................................................... 28 cfgDNSDomainNameFromDHCP (Read or Write).............................................................................................. 28 cfgStorageModule.............................................................................................................................................................29 cfgStorageModuleStorageMode....................
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for Dell EMC OpenManage Enterprise Modular (OME – Modular). Topics: • • • • New in this release Supported RACADM Interfaces RACADM Command Options Other documents you may need New in this release ● Added the attribute, switch- to the command,connect to facilitate connection to I/O module serial consoles.
Table 1. Details of RACADM command options (continued) Option Description -S Specifies that RACADM should check for invalid certificate errors. RACADM stops the execution of the command with an error message if it detects an invalid certificate. -i Specifies the index number for the indexed group, if applicable. -g Specifies the group name, if applicable. -o objectname Specifies the object name, if applicable. -m objectname Specifies the module. Table 2.
2 RACADM sub command details This section provides detailed descriptions about the RACADM subcommands, including the syntax and valid entries.
● # (pound) ● ASCII code 32 (space) NOTE: The - (dash) character cannot be the first character of the string, regardless of whether the string is quoted. There are different escaping rules for double quotation marks. There are different escaping rules for using single quotation mark and double quotation marks.
? ? arp chassisaction config ...
Table 4. racadm arp (continued) Address HWtype HWaddress Flags Mask Iface 192.168.1.120 ether 90:b1:1c:f4:32:09 C pub 192.168.0.121 ether 90:b1:1c:f4:34:f4 C pub chassisaction Description Executes the turn on, turn off, power cycle, or reset operation. Synopsis Input racadm chassisaction [-m ] ● -m—Must be one of the following values: ○ chassis—Default state if -m is not specified.
● --pending— Pending requests to join the group ● --discovered— Discovered chassis in the wired environment Examples ● Executes on a leader, adds a stand-alone chassis to the group: racadm chassisgroup add -m 192.168.0.
○ Critical ○ Warning ○ Info ● -b—The subcategory used to filter the records. Provide multiple subcategories using a "," as the delimiter. The value is case-insensitive.
cmcchangeover Description Changes the redundant state of the management module from active to standby and standby to active. Synopsis racadm cmcchangeover Input racadm cmcchangeover Example NA NOTE: During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power state is displayed after the inventory is refreshed. config Description Modifies the configuration properties of the management module.
CAUTION: When run from the OME–Modular serial console, the connect -b option stays connected until the management module resets or the serial console is terminated. This connection is a potential security risk. NOTE: The racadm connect to server prompts you to enter the iDRAC credentials for connecting to the server.
○ server ○ switch If the module type is not specified, the default type is server. NOTE: Switches must support Ethernet management. ● -u—The username for servers must be 'root'. ● -p—Password for the given username. For a server, the password must be 1-20 characters with ASCII value in the 32-126 range. NOTE: FC IOMs (MXG610s) do not support colon, ":", in passwords. NOTE: You can configure only the "root" user password for servers, using the deploy command.
Synopsis racadm faultlist view $ racadm faultlist view Example SubSystem = System.Modular.7 Message = CPU 1 is absent InstanceId = Fault#02200004#1 Severity = Critical MessageId = CPU0003 SubSystem = PowerSupply Message = The power input of power supply 1 is lost. InstanceId = Fault#02200005#1 Severity = Critical MessageId = PSU0003 SubSystem = PowerSupply Message = The power input of power supply 5 is lost.
● Display an indexed group: racadm getconfig -g cfgUserAdmin -o cfgUserAdminPassword -i 2 ● Display information about the service tag of the storage module: racadm getconfig -g cfgStorageModule -m storage-<1 to 8> -o cfgStorageModuleServiceTag ● Display all available configuration groups: racadm getconfig -h getmodinfo Description Gets module configuration and status information.
getpbinfo Description Synopsis Input Gets power budget status information. If there is no power supply to the PSU, the output of the command is displayed as Input Lost. If there is a mismatch in the power source, for example, a PSU of 220 Volts and PSU of 110 Volts are combined, then the output of the command is displayed as Configuration Error.
A N/A [Server Module 1 W 2 A 3 W 4 A 5 W 6 W 7 W 8 W Power Allocation SLOT-1 1 Extension (1) N/A SLOT-3 1 Extension (3) N/A SLOT-5 1 SLOT-6 1 SLOT-7 1 SLOT-8 1 Table] ON PowerEdge N/A N/A ON PowerEdge N/A N/A ON PowerEdge ON PowerEdge ON PowerEdge ON PowerEdge 605 MX840c N/ 792 MX840c N/ 227 MX740c 228 MX740c 240 MX740c 622 MX740c getpminfo Description Synopsis Input Example Gets power management status information.
Input Redundancy Reserve Input Power Allocated to Servers Input Power Allocated to Chassis Infrastructure Total Input Power Available for Allocation Standby Input Power Capacity = = = = = Not Applicable Not Applicable Not Applicable 2384 W (8134 BTU/h) Not Applicable getsensorinfo Description Displays system sensors.
Not OK PWR N/A ● 6 PS-6 Slot Empty racadm getsensorinfo -c Sensor Type: Fan 1 Fan-1 2 Fan-2 3 Fan-3 4 Fan-4 5 Fan-5 6 Fan-6 7 Fan-7 8 Fan-8 9 Fan-9 Not OK OK OK OK OK Not OK OK OK OK N/A rpm 17174 rpm 17238 rpm 17081 rpm 14499 rpm N/A rpm 14502 rpm 14505 rpm 14479 rpm Sensor Type: Temp 1 Chassis Inlet Temperature -7 47 Sensor Type: Power 1 PS-1 2 PS-2 3 PS-3 4 PS-4 5 PS-5 6 PS-6 N/A N/A N/A N/A N/A N/A N/A N/A
Synopsis racadm ifconfig ping Description Synopsis Sends ICMP echo packets on the network. racadm ping Input —The IP address of the remote endpoint to ping. Example To ping ip address 192.168.0.1 racadm ping 192.168.0.1 ping6 Description Synopsis Sends ICMP echo packets on the network. racadm ping6 Input —The IPv6 address of the remote endpoint to ping.
● Removes the MCM grouping functionality. NOTE: The reset_config, reset_all, racresetcfg, FIPS_MODE ON/OFF workflow clear the database and the user information is not retained. Hence, configuration restoration is logged in DELL_INTERNAL_PROCESS. NOTE: If the member chassis undergoes a factory reset, it becomes a stand-alone chassis and not a member of the multichassis group. You can remove the member from the lead chassis.
Input ● -m—The option must be one of the following values: ○ switch-, where n = 1-6 ○ chassis—The default state if -m is not specified. ● -d—Enables DHCP for the Ethernet management port. ● -s—Enables static IP address, netmask, and gateway settings. NOTE: ○ Enter the IP address, netmask, and gateway as dotted decimal strings. ○ Command also supports VLAN Configuration. ● -v—VLAN settings has the following legal values: ○ If there are no arguments, it implies that the VLAN tag must be removed.
Example To execute a trace route for IP address 192.168.0.2: racadm traceroute 192.168.0.2 traceroute6 Description Synopsis Prints the route packets trace to the network host. racadm traceroute6 Input —The IPv6 address/hostname of the remote end point to trace.
3 OpenManage Enterprise Modular property database group and object descriptions You can configure a setting that does not have a hash sign (#) prefixed in the output. To modify a configurable object, use the — o option. Topics: • • • • cfgLanNetworking cfgStorageModule cfgUserAdmin cfgRacTuning cfgLanNetworking This group contains parameters to configure OME-Modular NIC for IPv4. One instance of the group is allowed.
3. racadm config -g cfglannetworking -o cfgDNSServer1 100.69.112.5 For Alternate DNS Server name use cfgDNSServer2 4. racadm config -g cfglannetworking -o cfgDNSRegisterRac 1 If step 1 is applied, to return to the original state. NOTE: You can modify the cfgDNSServer1 and cfgDNSServer2 only when cfgDNSServersFromDHCP is 0. Else, the static DNS server settings are ignored. NOTE: Disable Use DHCP for DNS Domain Name to configure the DNS Domain Name.
Legal Values ● 1 — True ● 0 — False Default 0 NOTE: For IPv6, only the DHCPv6 address or static address is registered. Example: racadm getconfig -g cfgLanNetworking cfgDNSServersFromDHCP=1 cfgDNSServer1=192.168.0.5 cfgDNSServer2=192.168.0.6 cfgDNSRacName=cmc-frankly cfgDNSDomainName=fwad.lab cfgDNSDomainNameFromDHCP=1 cfgDNSRegisterRac=1 cfgDNSRacName (Read or Write) Description Displays the management module name, which is Service Tag by default.
Default 0 This property is used only if DHCP is enabled for the IPv4 stack or if IPv6 and IPV6 autoconfig are enabled. The management module can obtain its DNS domain name from either a DHCP or DHCPv6 server, if the following properties are set to 1 (true): ● ● ● ● IPv4Enable NIC Enabled IPv6 Enabled Autoconfiguration Enabled The network administrator must ensure that these DHCP servers are configured to provide the same DNS domain name to the management module.
cfgStorageModuleServiceTag Description Synopsis Input Displays the service tag. cfgStorageModuleServiceTag= cfgStorageModuleServiceTag= Example cfgStorageModuleServiceTag=MX0000 cfgStorageModuleAssetTag Description Synopsis Input Displays the asset tag. cfgStorageModuleAssetTag= cfgStorageModuleAssetTag Example cfgStorageModuleAssetTag=xxxxxx cfgConnectedSlots Description Synopsis Input Displays the connected slots.
cfgUserAdminPassword - Write Only Description The password for this user. User passwords are encrypted and cannot be seen or displayed after the property is written. Legal Values A string of up to 20 ASCII characters. The following characters are supported in a password: ● ● ● ● Default Uppercase letters Lowercase letters Numbers—0-9 Special characters—/, -, _, .