Users Guide

Table Of Contents
Table 2. MX7000OME-Modular 1.30.10 and previous solution baselines (continued)
Validated
MX Stack
Catalog
Version
NA 20.07.00 20.10.00 21.04.00 21.07.00
Componen
t
v1.10.20 v1.20.00 v1.20.10 v1.30.00 v1.30.10 Catalog
exceptions
Channel
Adapter
Firmware
32G
OpenMana
ge
Enterprise
Modular
1.10.20 1.20.00 1.20.10 1.30.00 1.30.10
MX9116n
Fabric
Switching
Engine
OS10
10.5.0.5*
10.5.0.7***
10.5.0.9
10.5.1.6***
10.5.1.7***
10.5.1.9
10.5.2.3Factory
install only***
10.5.2.4***
10.5.2.6
10.5.2.6
MX5108n
Ethernet
Switch
OS10
10.5.0.5*
10.5.0.7***
10.5.0.9
10.5.1.6***
10.5.1.7***
10.5.1.9
10.5.2.3Factory
install only***
10.5.2.4***
10.5.2.6
10.5.2.6
MX5016s
Storage
Sled
2.40 2.40 2.40 2.40 2.40
MX5000s
SAS IOM
1.0.9.6 1.0.9.8 1.0.9.8 1.0.9.8 1.0.9.8
MXG610s 8.1.0_lnx3 8.1.0_lnx3 8.1.0_lnx3 9.0.1a 9.0.1a No catalog update
or DUP
Network
IOM ONIE
NA NA NA 3.35.5.1-23 3.35.5.1-23
Delta AC
PSU
68.5F 68.5F 68.5F 68.5F 68.5F Manual DUP
Artesyn AC
PSU
36.6C 36.6C 36.6C 36.6C 36.6C Manual DUP
*Update to operating system 10.5.0.9 and then to 10.5.1.9 or 10.5.2.6. Run the X.509v3 certificate upgrade script before
upgrading any OS versions. For more details see, OS10 firmware update matrix.
**Update using individual DUP or obtain from the Latest component firmware versions on Dell.com catalog.
***Update restrictions apply. For more information, see OS10 firmware update matrix.
Before updating MX7000, check the PSU version. If the PSU version is 00.36.6B, then update the PSU. For details, see https://
www.dell.com/support/home/en-us/drivers/driversdetails?driverid=5tc17&oscode=naa&productcode=poweredge-mx7000.
NOTE:
Updating the MXG610s FC IOM is not supported from the OME-Modular user interface. Use the Brocade interface
on the IOM.
NOTE: Updating MX9116n or MX5108n using catalog method is not supported for OME-M versions 1.20.10 and lower. It is
supported from 1.30.00 onwards.
NOTE: As these update instructions include updates to various components of the solution, there is a possibility of traffic
impact to existing workloads. It is recommended that the updates are applied only during a regular single maintenance
window.
Updating firmware for PowerEdge MX solution 17