Users Guide
Table Of Contents
- Dell EMC OpenManage Enterprise-Modular Edition for PowerEdge MX7000 Chassis User's Guide
- Contents
- Overview
- Updating firmware for PowerEdge MX solution
- MX7000 Solution Baselines
- Upgrading ethernet switch using DUP
- OME-Modular licenses
- Logging in to OME-Modular
- Logging in to OME–Modular as local, Active Directory, or LDAP user
- Logging in to OME-Modular using OpenID Connect
- OME-Modular home page
- Viewing device health
- Setting up chassis
- Initial configuration
- Configuring chassis settings
- Managing chassis
- Chassis groups
- Controlling chassis power
- Backing up chassis
- Restoring chassis
- Exporting chassis profiles
- Managing chassis failover
- Troubleshooting in chassis
- Blinking LEDs
- Interfaces to access OME-Modular
- Viewing chassis hardware
- Viewing chassis alerts
- Viewing chassis hardware logs
- Configuring OME–Modular
- Viewing current configuration
- Configuring users and user settings
- Configuring login security settings
- Configuring alerts
- Managing compute sleds
- Managing Profiles
- Managing storage
- Managing templates
- Managing identity pools
- Ethernet IO Modules
- MX Scalable Fabric architecture
- SmartFabric Services
- Managing networks
- Managing Fibre Channel IOMs
- Managing firmware
- Monitoring alerts and logs
- Monitoring audit logs
- Use case scenarios
- Troubleshooting
- Storage
- Firmware update is failing
- Storage assignment is failing
- SAS IOM status is downgraded
- SAS IOM health is downgraded
- Drives on compute sled are not visible
- Storage configuration cannot be applied to SAS IOMs
- Drives in OpenManage are not visible
- iDRAC and OpenManage drive information do not match
- The assignment mode of storage sled is unknown
- Unable to access OME-Modular using Chassis Direct
- Troubleshooting lead chassis failure
- Storage
- Recommended slot configurations for IOMs
- Creating validated firmware solution baseline using Dell Repository Manager
- Upgrading networking switch using different OS10 DUP versions
- Upgrading networking switch using CLI
Table 26. Supported IOM slot matrix (continued)
Slot A1 Slot A2 Slot B1 Slot B2
10GBT PTM Empty 10GBT PTM Empty
MX9116n MX9116n MX9116n Empty
MX5108n MX5108n MX5108n Empty
MX7116n MX7116n MX7116n Empty
25G PTM 25G PTM 25G PTM Empty
10GBT PTM 10GBT PTM 10GBT PTM Empty
MX9116n MX9116n MX5108n MX5108n
MX9116n MX9116n 25G PTM 25G PTM
MX9116n MX9116n 10GBT PTM 10GBT PTM
MX9116n MX7116n MX5108n MX5108n
MX7116n MX9116n MX5108n MX5108n
MX9116n MX7116n 25G PTM 25G PTM
MX7116n MX9116n 25G PTM 25G PTM
MX9116n MX7116n 10GBT PTM 10GBT PTM
MX7116n MX9116n 10GBT PTM 10GBT PTM
MX7116n MX7116n MX5108n MX5108n
MX7116n MX7116n 25G PTM 25G PTM
MX7116n MX7116n 10GBT PTM 10GBT PTM
MX5108n MX5108n MX9116n MX9116n
MX5108n MX5108n MX7116n MX7116n
MX5108n MX5108n MX9116n MX7116n
MX5108n MX5108n MX7116n MX9116n
MX5108n MX5108n 25G PTM 25G PTM
MX5108n MX5108n 10GBT PTM 10GBT PTM
25G PTM 25G PTM MX9116n MX9116n
25G PTM 25G PTM MX7116n MX7116n
25G PTM 25G PTM MX9116n MX7116n
25G PTM 25G PTM MX7116n MX9116n
25G PTM* 25G PTM* 10GBT PTM* 10GBT PTM*
10GBT PTM 10GBT PTM MX9116n MX9116n
10GBT PTM 10GBT PTM MX7116n MX7116n
10GBT PTM 10GBT PTM MX9116n MX7116n
10GBT PTM 10GBT PTM MX7116n MX9116n
10GBT PTM* 10GBT PTM* 25G PTM* 25G PTM*
LEGEND:
*—Combining two types of Pass-Through Modules (PTMs) is supported.
Recommended slot configurations for IOMs