Lorsque le châssis est promu en tant que maître lors du workflow Procéder au retrait du châssis ou Promouvoir en tant que
châssis maître.
REMARQUE : La tâche Synchronisation des paramètres de sécurité MCM n’est pas créée dans le cadre de la propagation
des paramètres du fournisseur OIDC du châssis maître vers le châssis membre.
Identifier GUID-FB621B39-E6F1-4F08-BCFA-F71FE16578C6
Version 4
Status Released
Viewing job details
The Fabric Manager on-boarding is initiated when a Fabric Manager failover occurs in the IOM cluster. When a new Fabric Manager
is discovered, OME-Modular initiates the on-boarding process to reestablish communication with the IOM cluster. In certain scenarios,
multiple switchovers may occur within a short timespan resulting in failure of the tasks that are already in-progress. Only the last task is
completed successfully. Following are the scenarios when multiple switchovers could occur:
MM reset
MM upgrade or switchover
Inter-chassis link online insertion removal
MM online insertion removal
IOM main upgrade
IOM main reset
Fab-D congestions—Reasons for the congestion include downloading huge files that cause the FAB-D to drop other traffic
The details of the assigned MAC addresses for the respective NIC partitions are displayed on the Jobs Details page, that are based on
the configuration results from iDRAC.
To view the details of a job:
1. On the Jobs page, select the job of which you want to view the details.
A summary of the job is displayed on the right side of the Jobs page.
2. Click View Details.
The Job Details page is displayed.
The details including name, description, execution details, and the details of the system on which the job was run, are displayed.
On Job Details page, you can perform the following tasks:
Restart the job
Export details of the job in a .csv format to a local drive on your system or a network share
NOTE: The Restart option for the MCM onboarding task for adding a member chassis is disabled irrespective of the job status.
Sometimes after a firmware update, racreset or management module failover, a message stating that the alerts could not be
retrieved is displayed. The message that is displayed does not impact the functionality of OME–Modular.
Identifier
GUID-41D797DE-607C-42C2-AC43-5D2B58CF5E3D
Version 1
Status Translation Validated
Exportation des détails de l’exécution d’une tâche
Vous pouvez exporter les détails de l’exécution de la tâche au format .txt sur un disque local sur votre système.
Pour exporter les détails de la tâche :
Sur la page Détails de la tâche, cliquez sur Exporter dans l’onglet Détails de l’exécution.
Les détails de l’exécution sont téléchargés sur un disque local de votre système, au format .txt.
Les détails de l’exécution de la tâche sont : les dates de début et de fin de la tâche, l’état, la durée écoulée, le système cible sur lequel la
tâche est exécutée et le message de la tâche.
REMARQUE :
Toujours télécharger le rapport au format .txt. Dans le rapport, l’heure s’affiche au format 24 heures GMT, tandis que
l’interface utilisateur affiche l’heure au format 12 heures.
Surveillance des journaux d'audit 145