Users Guide
Table Of Contents
- 适用于 PowerEdge MX7000 机箱的 Dell EMC OpenManage Enterprise-Modular Edition 版本 1.30.00 用户指南
- 概览
- 更新 PowerEdge MX 解决方案的固件
- OME-Modular 许可证
- 登录 OME - Modular
- 管理计算底座
- 管理配置文件
- 管理存储
- 管理模板
- 管理标识池
- 以太网 IO 模块
- MX 可扩展结构架构
- SmartFabric 服务
- 管理网络
- 管理光纤信道 IOM
- 管理固件
- 监测警报和日志
- 监测审核日志
- 使用案例场景
- 故障排除
- 建议的 IOM 插槽配置
- 使用不同的 OS10 DUP 版本升级网络交换机
- Upgrading networking switch using CLI
Table 30. Command description
Command Description
OS10# show image status View the current software download status.
e. Install the 10.5.0.5 software image in EXEC mode.
Table 31. Command description
Command Description
OS10# image install image-url
Example:
OS10# image install image://filename.bin
Install the software image.
f. (Optional) View the status of the current software install in EXEC mode.
Table 32. Command description
Command Description
OS10# show image status View the status of the current software install.
g. Change the next boot partition to the standby partition in EXEC mode. Use the active parameter to set the next boot partition
from standby to active.
Table 33. Command description
Command Description
OS10# boot system standby Change the next boot partition to standby.
h. (Optional) Check whether the next boot partition has changed to standby in EXEC mode.
Table 34. Command description
Command Description
OS10# show boot detail Check whether the next boot partition has changed.
i. Reload the new software image in EXEC mode.
Table 35. Command description
Command Description
OS10# reload Reload the new software.
j. After the installation is complete, enter the show version command to check if the latest version of the software that you have
installed is running in the system.
The example below shows that the 10.5.0.5 software is installed and running on the system.
OS10# show version
MX9116N-A2# show version
Dell EMC Networking OS10 Enterprise
Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved.
OS Version: 10.5.0.5
Build Version: 10.5.0.5.661
Build Time: 2020-02-15T00:45:32+0000
System Type: MX9116N-ON
Architecture: x86_64
Up Time: 1 day 20:37:53
MX9116N-A2#
2. Run the command, show smartfabric cluster member, in the main networking switch. Confirm that the STATUS of the
upgraded switch is ONLINE in the command output, after it has reloaded. The networking switches with version 10.5.01 and higher
uses SFS CLI, whereas the lower versions like 10.4.0E(R3S) and 10.4.0E(R4S) use python /opt/dell/os10/bin/rest-
service/tool/dnv_cli.py show cluster command. For steps to identify the main IOM, see upgrading from versions earlier than
10.5.0.5 section.
Upgrading networking switch using CLI 145