CLI Guide

Table 369. SYSCFG Error Codes and Messages (continued)
Error Code Message
211 Unsupported file name extension.Supported file name extension is XML
212 Unsupported file name extension.Supported file name extensions
are .ini, .log, .bat, .ids, .lst, and .txt.
Failures And Solutions
The following table lists the common SYSCFG failures and their solutions.
Table 370. SYSCFG Failures and Solutions
Failure Messages Solutions
Generic failure. Indicates iDRAC is in bad state. Reboot iDRAC.
New value not valid. Make sure the changed value is valid.
Cannot disable this orderedLists
entries.
BIOS does not support enabling or disabling of a particular boot order object.
System busy, try again later. Retry as iDRAC is busy with internal processing.
Unable to connect iDRAC data
manager.
Start data manager service using srvadmin_services (specific to Linux).
System Services and/or CSIOR
disabled.
Enable CSIOR from <F2> screen.
UPINIT Common Error Codes And Messages
The UPINIT utility checks your commands for correct syntax. When you enter a command, a message is displayed stating the
results of the command.
Failure Messages
The UPINIT utility failure messages provide error codes to help diagnose why some commands do not succeed. Table below lists
error codes and messages common to Linux and Microsoft Windows PE environments.
Table 371. UPINIT Common Error Codes and Messages
Error Code Message
0 Dell Utility Partition created successfully.
1 Error: Disk ID not specified.
2 Error: SIZE not specified.
3 Error: Utility Partition Image file not specified.
4 Error: DRMK Path not specified.
5 Error: Dell Utility Partition already exits. Please use --overwrite
option to upgrade or overwrite.
6 Error: Partitions exists. Please clear all the partitions before running
upinit.sh.
7 Error: DOS file(s) not found at the specified path.
8 Error: UP IMAGE not found at the specified location.
9 Error: format failed.
212 Messages And Codes