CLI Guide

memremap
Table 272. memremap
Valid Arguments off, auto
Description
Sets the memory remapping to off or auto.
Example:
A:>syscfg --memremap=off
memremap=off
mouse
Table 273. mouse
Valid Arguments on, off
Description
Turns the mouse controller on or off.
This option can be replicated.
Example:
A:>syscfg --mouse=off
mouse=off
noraidprompt
Table 274. noraidprompt
Valid Arguments NA
Description
Specifies that the BIOS must not prompt for confirmation when changing the mode
of a RAID controller. This option can only be used with the --embscsiraid or --
embscsiraidchb options.
Without this option, the user is prompted during POST to confirm the change of a
RAID controller from RAID (SCSI) to SCSI (RAID). This option is not replicated.
CAUTION: When changing a RAID controller from SCSI to RAID or from
RAID to SCSI, data is lost on the affected hard drives. The warning
message for this data is not displayed if you use the --noraidprompt
option. To avoid data loss, back up any information on the hard drives
before changing the type of controller used with the drives
Example:
A:>syscfg --embscsiraid=raid --noraidprompt
embscsiraid=raid
SYSCFG 121