Release Notes

If you set the username using syscfg username option, Serial over LAN (SOL) access for the corresponding user will be
enabled by default. You can disable SOL access for a user using syscfg solaction --userid=<userid> --action=disable
command.
RAIDCFG
When creating virtual disks, the chunk (stripe) size is always in KBs. Do not specify any units of measure for the chunk size.
When providing multiple physical disks for the "create virtual disk" command, do not separate the disks with spaces.
For example, "-ad=1:4, 1:5" causes an error. The correct way to input multiple physical disks is "-ad=1:4,1:5,1:6" or "-
ad=1:4:0,1:5:0,1:6:0".
If you change the controller mode from SCSI to RAID mode, data loss may occur. Back up any data you require before
changing the modes.
For creating RAID0 on any SWRAID controller minimum two hard-disks to be connected.
SwRAID does not support blink/unblink operation.
RAIDCFG operations can not be performed on HBA330 and AHCI non-raid mode.
Known Issues
SYSCFG Issues
In DRAC , the --virtualmedia and --vflash options do not work if there is an active virtual media session. Disconnect the
virtual media using the DRAC GUI. Log into DRAC. Click Media > Virtual Media > Disconnect.
The syscfg --bootseq command detects CD-ROM with SAS/SATA controllers as unknown.unknown.n-1.
On R815, syscfg power --profile option allows to set apc. Though apc is not supported on R815, syscfg does not throw an
error message.
The legacy attribute values enable and disable are also supported for 12G systems for backward compatibility. In future
releases, these arguments might be deprecated. Try to use the values shown in help message for BIOS options for 12G
server.
Some options may not be present on all systems, which may be due to the BIOS version or hardware feature set. The usage
information generated by running SYSCFG without arguments shows only those options that are valid for your system.
The option for powerctl, which is softshutdown, does not work on Windows PE.
The --solbitrate option in solcfgparams and the --mgscommbitrate option in serialcfgparams accept a baud rate of 57600,
but tools such as "ipmish" and "solproxy" do not function at that baud rate for PowerEdge systems.
Intel(R) Gigabit 4P I350-t rNDC card x32 driver shows the following warning message Windows cannot verify the publisher
of this driver software on Win7 x32, while injecting due to expired certificate.
RAIDCFG Issues
If both the software and hardware RAID is enabled, raidcfg will show the same controller ID for both the controllers. Disable
either software raid or insert the hardware raid other than PCIe slot 0 in the server.
You can assign up to 10 Global hot spares using Raidcfg. Use the Dell OpenManage Server Administrator Storage
Management for assigning more than 10 Global hot spares.
Raidcfg does not support Non RAID (Volume) mode on S140 controller.
On Software RAID Controller, NVMe PCIe-SSD add-on card is not supported.
Lockdown Mode enabled will not impact with Raidcfg functionality.
On Dell PERC H740 controllers, conversion of a RAID Capable Disk to Non-RAID disk and vice versa is not supported using
RAIDCFG.
RACADM Issues
If you use virtual media to boot into Windows PE, executing certain RACADM commands may cause Windows PE to crash.
4