CLI Guide

Mandatory Options and
Arguments
Optional Parameters Valid Parameters
Arguments
Description
Example:
A:>raidcfg -ctrl -ac=ephs -c=2
RAIDCFG Command successful!
--ctrl -c=id -
ac=dphs
or
controller
controllerid=id
action=disableper
sistenthotspare
NA NA
Disables the persistent slot corresponding to the hot
spare drive. If the drive is removed from the slot and
any drive is inserted, the slot stops functioning as a
hot spare. You must manually assign the drive as a hot
spare again.
Example:
A:>raidcfg -ctrl -ac=dphs -c=2
RAIDCFG Command successful!
Setting And Displaying The PCIe Link Speed
The following table lists the RAIDCFG options, parameters, and pre-dened arguments for setting and displaying the Peripheral Component
Interconnect Express (PCIe) link speed of the controller.
Table 365. Setting and Displaying the PCIe Link Speed
Mandatory Options and
Arguments
Optional Parameters Valid Parameters
Arguments
Description
--ctrl -c=id -
ac=spciels -spd=<2
| 3>
or
controller
controllerid=id
action=setpcielin
kspeed speed=<2 |
3>
NA NA
Sets the PCIe link speed of the controller to PCIe
Generation 2 or 3.
NOTE: Reboot the system to apply the
setting.
Example:
A:>raidcfg -ctrl -c=2 -ac=spciels -
spd=2
RAIDCFG Command successful!
--ctrl -c=id -
ac=gpciels
or
controller
controllerid=id
action=getpcielin
kspeed
NA NA
Displays the PCIe link speed of the controller.
Example:
A:>raidcfg -ctrl -c=2 -ac=gpciels
RAIDCFG Command successful!
Supported Controllers And Firmware Versions For PCIe Link Speed
The following table lists the controllers and minimum supported rmware versions for PCIe link speed.
216