CLI Guide

embscsiraidchb
Table 260. embscsiraidchb
Valid Arguments raid, scsi
Description
Sets the second channel on an embedded RAID controller to SCSI or RAID. This option is
only valid for systems that support RAID/RAID and RAID/SCSI settings for channels A and
B. This option can be replicated.
Example:
A:>syscfg --embscsiraidchb=raid
embscsiraidchb=raid
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embsdcardredundancy
Table 261. embsdcardredundancy
Valid Arguments mirrormode, disable
Description
Sets the redundancy to mirrormode or disabled.
If set to mirrormode, read-write operation occurs on both the secure digital (SD) cards. If
one of the SD cards fails and is replaced, on booting, the data is copied to that SD card.
If set to disable, read-write operation occurs only on SD card 1.
On Blade systems, disable the vash key to congure this option.
Example:
A:>syscfg --embsdcardredundancy=mirrormode
embsdcardredundancy=mirrormode
Applicable Systems This option is degraded.
redmem
Table 262. redmem
Valid Arguments o, spare, mirror, DDDC
Description
Allows selection of the required redundant memory mode, or disables redundant memory.
This option can be replicated.
Example:
A:>syscfg --redmem=off
redmem=off
Applicable Systems PowerEdge systems with Intel Xeon 7500 series processor
SYSCFG 137