Release Notes

NOTE: Additionally, the --redmem option should not be issued with any other command and should be immediately followed
by a system reboot. This is important when you develop scripts that can alter the --redmem setting.
For options that use text strings such as username, password, hostname, and community string, using characters such as <space>,
"<," ">," "|," "=" on the command line can be misinterpreted by the command line parser and may cause errors. To avoid such errors,
use only alphanumeric characters.
If you set the username using syscfg username option, Serial over LAN (SOL) access for the corresponding user will be enabled by
default. You can disable SOL access for a user using
syscfg solaction --userid=<userid> --action=disable command.
RAIDCFG
When creating virtual disks, the chunk (stripe) size is always in KBs. Do not specify any units of measure for the chunk size.
When providing multiple physical disks for the "create virtual disk" command, do not separate the disks with spaces.
For example, "-ad=1:4, 1:5" causes an error. The correct way to input multiple physical disks is "-ad=1:4,1:5,1:6" or "-
ad=1:4:0,1:5:0,1:6:0".
If you change the controller mode from SCSI to RAID mode, data loss may occur. Back up any data you require before changing the
modes.
For creating RAID0 on any SWRAID controller minimum two hard-disks to be connected.
SwRAID does not support blink/unblink operation.
RAIDCFG operations can not be performed on HBA330 and AHCI non-raid mode.
Table 1. Support Matrix for controller cards
Controller type OSD support with
PowerEdge MX740c and
PowerEdge MX840c
OSD support with
MX5016s
Virtual disk, Physical
disk support with
Compute backplanes
Virtual disk, Physical
disk support using
MX5016s HDDs
H745P MX YES NO YES YES
H730P MX YES N/A YES N/A
HBA330 MX YES N/A PD = YES ; VD = NO N/A
S140 (SATA) YES YES N/A YES
HBA330 MMZ NO NO PD = YES ; VD = NO PD = YES ; VD = NO
S140 + NVMe disks NO N/A YES N/A
Known Issues
SYSCFG Issues
In DRAC , the --virtualmedia and --vflash options do not work if there is an active virtual media session. Disconnect the virtual media
using the DRAC GUI. Log into DRAC. Click Media > Virtual Media > Disconnect.
The syscfg --bootseq command detects CD-ROM with SAS/SATA controllers as unknown.unknown.n-1.
On R815, syscfg power --profile option allows to set apc. Though apc is not supported on R815, syscfg does not throw an error
message.
The legacy attribute values enable and disable are also supported for 12G systems for backward compatibility. In future releases, these
arguments might be deprecated. Try to use the values shown in help message for BIOS options for 12G server.
Some options may not be present on all systems, which may be due to the BIOS version or hardware feature set. The usage
information generated by running SYSCFG without arguments shows only those options that are valid for your system.
The option for powerctl, which is softshutdown, does not work on Windows PE.
The --solbitrate option in solcfgparams and the --mgscommbitrate option in serialcfgparams accept a baud rate of 57600, but tools
such as "ipmish" and "solproxy" do not function at that baud rate for PowerEdge systems.
Intel(R) Gigabit 4P I350-t rNDC card x32 driver shows the following warning message “Windows cannot verify the publisher of this
driver software” on Win7 x32, while injecting due to expired certificate.
4
Dell EMC OpenManage Deployment Toolkit 6.2 for Microsoft Windows Preinstallation Environment Release Notes