CLI Guide
The set of converted commands are available in dtktoracadm_dict.map. For more information see, Dell EMC OpenManage Deployment
Toolkit User's Guide or Dell EMC OpenManage Deployment Toolkit Installation Guide. The following table lists the set of commands
available:
Table 243. SYSCFG equivalent RACADM commands
Group SYSCFG Commands Equivalent RACADM Commands
iDRAC Settings
lcp --dnsdhcp iDRAC.IPv4.DNSFromDHCP
lcp --domainname iDRAC.NIC.DNSDomainName
lcp --dnsracname iDRAC.NIC.DNSRacName
lcp --dnsregisterrac iDRAC.NIC.DNSRegister
--idractype iDRAC.Info.Type -z legacy
--autoneg iDRAC.NIC.Autoneg
--gateway iDRAC.IPv4.Gateway
--ipaddress iDRAC.IPv4.Address
--macaddress iDRAC.NIC.MACAddres
--nicselectionfailover iDRAC.NIC.Failover
--subnetmask iDRAC.IPv4.Netmask
--vlanid iDRAC.NIC.VLanID
--dnsserver1v6 get iDRAC.IPv6.DNS1
--dnsserver2v6 get iDRAC.IPv6.DNS2
--gatewayv6 iDRAC.IPv6.Gateway
--ipv6address1 iDRAC.IPv6.Address1
--ipv6address2 iDRAC.IPv6.Address2
--linklocaladdrv6 iDRAC.IPv6.LinkLocalAddress
--prexlengthv6 iDRAC.IPv6.PrexLength
--connectionmode iDRAC.IPMISerial.ConnectionMode
--msgcommbitrate iDRAC.IPMISerial.BaudRat
--msgcommowctrl iDRAC.IPMISerial.FlowControl
--tmcfghandshakectrl iDRAC.IPMISerial.HandshakeControl
--tmcfglineediting iDRAC.IPMISerial.LineEdit
--tmcfgnewlineseq iDRAC.IPMISerial.NewLineSeq
--solcharaccuminterval iDRAC.IPMISOL.AccumulateInterval
--solbitrate iDRAC.IPMISOL.BaudRate
--solprivlevel iDRAC.IPMISOL.MinPrivilege
--solcharsendthreshold iDRAC.IPMISOL.SendThreshold
BIOS Option Settings
--HddSeq BIOS.BiosBootSettings.HddSeq
Boot Settings
--BootMode BIOS.BiosBootSettings.BootMode
128 SYSCFG