CLI Guide

MemVolt
Table 202. MemVolt
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: NA
On Dell’s 12th generation PowerEdge and later systems: AutoVolt, Volt15V, Volt135V
NOTE: Volt15V represents 1.5 Volt and Volt135V represents 1.35 Volts.
Description
Sets the DIMM voltage selection.
Example:
A:>syscfg --MemVolt=AutoVolt
MemVolt=AutoVolt
Applicable Systems Dell’s 12th generation PowerEdge and later systems
MonitorMwait
Table 203. MonitorMwait
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: NA
On Dell’s 12th generation PowerEdge and later systems: Enabled, Disabled
Description
Enables or disables Monitor/Mwait instructions. You can disable Monitor/Mwait only when
C state is disabled in Custom mode.
Example:
A:>syscfg --MonitorMwait=Enabled
MonitorMwait=Enabled
Applicable Systems Dell’s 12th generation PowerEdge and later systems
PowerSaver
Table 204. PowerSaver
Valid Arguments
On systems prior to Dell’s 13th generation PowerEdge systems: NA
On Dell’s 13th generation PowerEdge and later systems: Enabled, Disabled
Description
Enables or disables the power-saving Dell Active Power Controller (DAPC) algorithm.
Example:
A:>syscfg --PowerSaver=Enabled
PowerSaver=Enabled
Applicable Systems Dell’s 13th generation PowerEdge and later systems
112 SYSCFG