CLI Guide
SecurityFreezeLock
Table 182. SecurityFreezeLock
Valid Arguments
• On systems prior to Dell’s 12th generation PowerEdge systems: NA
• On Dell’s 12th generation PowerEdge and later systems: Enabled, Disabled
Description
Sends the Security Freeze Lock command to the embedded SATA drives during power-on
self-test (POST). The option is applicable only to ATA and AHCI, and not to RAID.
Example:
A:>syscfg --SecurityFreezeLock=Enabled
SecurityFreezeLock=Enabled
Applicable Systems Dell’s 12th generation PowerEdge and later systems
Serial Communication
You can manage the serial port settings using the options in this group.
ConTermType or conterm
Table 183. ConTermType or conterm
Valid Arguments
• On systems prior to Dell’s 12th generation PowerEdge systems: vt100, ansi
• On Dell’s 12th generation PowerEdge and later systems: Vt100, Vt220, Ansi
Description
Sets the console terminal type. On some systems, vt100 may also set the terminal type to
vt220. This option is available on all supported systems that support console redirection.
This option can be replicated.
Example:
A:>syscfg --conterm=vt100
conterm=vt100
Applicable Systems All PowerEdge systems
ExtSerialConnector or extserial
Table 184. ExtSerialConnector or extserial
Valid Arguments
• On systems prior to Dell’s 12th generation PowerEdge systems: com1, com2, rad
104 SYSCFG