Release Notes
• Intel Ethernet Network Adptr XXV710-DA2
• NetXtreme BCM5719/5720 1Gbps devices
• NetXtreme-E BCM574xx 10Gbps/25Gbps devices
• Mellanox ConnectX-4 Dual Port 100 GbE QSFP Network Adapter
• Intel X550 rNDC
• Intel 10GbE 4P X710
• Added support for the following Dell PowerEdge servers:
• PowerEdge R740
• PowerEdge R740XD
• PowerEdge R640
• PowerEdge R940
• PowerEdge C6320P
• PowerEdge C4140
• PowerEdge C6420
• PowerEdge R7920
• PowerEdge R7425
• PowerEdge R7415
• PowerEdge R6415
• PowerEdge R540
• PowerEdge R440
• PowerEdge T440
• PowerEdge M640
• PowerEdge FC640
• PowerEdge T640
• PowerEdge C6400
NOTE:
For the list of supported operating systems and Dell servers, see the
Dell Systems Software Support Matrix
at dell.com/
openmanagemanuals.
Important Notes
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/).
Use both DTK and the Server Administrator from the same release version to get complete supported features of Server Administrator.
DTK operating system deployment limitation:
DTK does not support operating system deployment, when multiple boot VDs exist on a single controller or when the server has multiple
boot controllers. If multiple boot controllers exist on the server, the boot VD must be created on any one of the controllers, and the boot
VD must be set as first boot device in system BIOS.
On debranded or rebranded servers, Deployment toolkit is not supported.
DTK does not support Linux operating system deployment in Non RAID (Volume) and SWRAID mode on s140 controllers.
SYSCFG
• Some options may not be present on all systems, which may be due to the BIOS version or hardware feature set. The usage
information generated by running SYSCFG without arguments shows only those options that are valid for your system.
• The --devseq option is present only if you have an available, bootable hard-disk partition. If this option is present in the configuration
file, but not present on your system, you will receive a usage error.
• To enable certain options, to reboot your system. Dell recommends you use the "reboot" command on shell prompt or press the Ctrl
+Alt+Del keys.
• It is required to perform a warm reboot after applying the SYSCFG settings changes on Dell’s 12th generation of PowerEdge systems.
• If you perform operations that change the --redmem option, reboot your system immediately. It is applicable to both command line
and
--infile usage.
NOTE:
Additionally, the --redmem option should not be issued with any other command and should be immediately followed
by a system reboot. This is important when you develop scripts that can alter the --redmem setting.
Dell EMC OpenManage Deployment Toolkit 6.1 for Embedded Linux Release Notes 3