CLI Guide

Table Of Contents
Table 188. SerialPortAddress or serialportaddrsel (continued)
Description
Sets the port address of the serial devices.
On systems prior to Dells 12th generation PowerEdge systems, when this option is
default, Serial Device 1 is set to COM port 1 and Serial Device 2 is set to COM port
2.
On systems prior to Dells 12th generation PowerEdge systems, when this option is
alternate, Serial Device 1 is set to COM port 2 and Serial Device 2 is set to COM
port 1.
This option can be replicated.
Example:
A:>syscfg --serialportaddrsel=default
serialportaddrsel=default
Applicable Systems Dells 11th generation PowerEdge and later systems
Slot Disablement
You can manage the slot disablement settings using the options in this group.
Slot
n
Table 189. Slot
n
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: NA
On Dells 12th generation PowerEdge and later systems: Enabled, Disabled,
BootDriverDisabled
Description
Controls the configuration of the installed card in the specified slot.
NOTE: The value of n in Slotn can be 110.
Example:
A:>syscfg --Slot1=Enabled
Slot1=Enabled
Applicable Systems Dells 12th generation PowerEdge and later systems
Slot
n
Bif
Table 190. Slot
n
Bif
Valid Arguments
On systems prior to 14G: NA
On 14G: x16, x4, x8, x4x4x8, x8x4x4
Description
Controls the configuration of the installed card in the specified slot. Where the value
of n in Slotn can be 1 or 2.
Example:
A:>syscfg --Slot1Bif=x8
Applicable Systems PowerEdge 14G and later systems
SYSCFG 99