CLI Guide
Table Of Contents
- Dell EMC OpenManage Deployment Toolkit Version 6.1 Command Line Interface Reference Guide
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1 or embnic1
- EmbNic1Nic2 or embnic1nic2
- EmbNic2 or embnic2
- EmbNic3 or embnic3
- EmbNic3Nic4 or embnic3nic4
- EmbNic4 or embnic4
- EmbVideo or embvideoctrl
- IoatEngine or ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid or integratedraid
- IntegratedSas or integratedsas
- InternalSdCard or embsdcard
- InternalSdCardRedundancy or embsdcardredundancy
- InternalUsb or internalusb
- InternalUsb1 or internalusbport1
- InternalUsb2 or internalusbport2
- OsWatchdogTimer or oswatchdogtimer
- SriovGlobalEnable or sriov
- UsbPorts or usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- IscsiDev1ConnChapType
- IscsiDev1ConnDhcpEnDis
- IscsiDev1ConnEnDis
- IscsiDev1ConnInterface
- IscsiDev1ConnProtocol
- IscsiDev1ConnTimeout
- IscsiDev1ConnVlanEnDis
- IscsiDev1ConnVlanId
- IscsiDev1ConnAuth
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse or datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher or dcustreamerprefetcher
- LogicalProc or logicproc
- Proc1Brand
- Proc1Id
- Proc1L2Cache
- Proc1L3Cache
- Proc1NumCores
- Proc2Brand
- Proc2Id
- Proc2L2Cache
- Proc2L3Cache
- Proc2NumCores
- Proc3Brand
- Proc3Id
- Proc3L2Cache
- Proc3L3Cache
- Proc3NumCores
- Proc4Brand
- Proc4Id
- Proc4L2Cache
- Proc4L3Cache
- Proc4NumCores
- Proc64bit
- ProcAdjCacheLine or adjcacheprefetch
- ProcBusSpeed
- ProcCores or cpucore
- ProcCoreSpeed
- ProcExecuteDisable or cpuxdsupport
- ProcHwPrefetcher or hwprefetcher
- ProcVirtualization or virtualization
- QpiBandwidthPriority or qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata or embsataraid
- eSataPort1
- eSataPort1Capacity
- eSataPort1DriveType
- eSataPort1Model
- SataPortA or sata0
- SataPortACapacity
- SataPortADriveType
- SataPortAModel
- SataPortB or sata1
- SataPortBCapacity
- SataPortBDriveType
- SataPortBModel
- SataPortC or Sata2
- SataPortCCapacity
- SataPortCDriveType
- SataPortCModel
- SataPortD or sata3
- SataPortDCapacity
- SataPortDDriveType
- SataPortDModel
- SataPortE or sata4
- SataPortECapacity
- SataPortEDriveType
- SataPortEModel
- SataPortF or sata5
- SataPortFCapacity
- SataPortFDriveType
- SataPortFModel
- SataPortG or sata6
- SataPortGCapacity
- SataPortGDriveType
- SataPortGModel
- SataPortH or sata7
- SataPortHCapacity
- SataPortHDriveType
- SataPortHModel
- SataPortI or sata7
- SataPortICapacity
- SataPortIDriveType
- SataPortIModel
- SataPortJ or sata7
- SataPortJCapacity
- SataPortJDriveType
- SataPortJModel
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- System Security
- AcPwrRcvry or acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt or inteltxt
- NmiButton or nmibutton
- PasswordStatus or pwdlock
- PwrButton or powerbutton
- SetupPassword or setuppwd
- SysPassword or syspwd
- SystemCpldVersion
- TcmActivation or tcmactivation
- TcmClear or tcmclear
- TcmSecurity or tcmsecurity
- TpmActivation or tpmactivation
- TpmClear or tpmclear
- TpmSecurity or tpmsecurity
- TpmStatus
- TpmInfo
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- SecureBootMode
- TpmPpiBypassClear
- TpmPpiBypassProvision
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge 12G Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype
- clearsel
- controlpanelaccess
- deviceguid
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
ConTermType or conterm
Table 183. ConTermType or conterm
Valid Arguments
● On systems prior to Dell’s 12th generation PowerEdge systems: vt100, ansi
● On Dell’s 12th generation PowerEdge and later systems: Vt100, Vt220, Ansi
Description
Sets the console terminal type. On some systems, vt100 may also set the terminal
type to vt220. This option is available on all supported systems that support console
redirection. This option can be replicated.
Example:
A:>syscfg --conterm=vt100
conterm=vt100
Applicable Systems All PowerEdge systems
ExtSerialConnector or extserial
Table 184. ExtSerialConnector or extserial
Valid Arguments
● On systems prior to Dell’s 12th generation PowerEdge systems: com1, com2, rad
● On Dell’s 12th generation PowerEdge and later systems: Serial1, Serial2,
RemoteAccDeviceDescription
Description
Sets the behavior of the external serial connector. When set to com1 , the BIOS
maps the external serial connector to COM port 1. The com1 setting is the default.
When set to com2 , the external serial connector is routed to the COM2 interface.
Terminal escape sequences can toggle the external connector between the system
(COM2) and the remote access device.
When set to rad , the external serial connector is routed to the remote access
device interface. Terminal escape sequences can toggle the external connector
between the system (COM2) and the remote access device.
This option can be replicated.
Example:
A:>syscfg --extserial=com1
extserial=com1
The --serialcomm option can be used with the external serial (--extserial) option
instead of the --conred (available on systems earlier than PowerEdge 9G systems)
option.
Applicable Systems All PowerEdge systems except Blade systems.
FailSafeBaud or fsbr
Table 185. FailSafeBaud or fsbr
Valid Arguments
● On systems prior to Dell’s 12th generation PowerEdge systems: 115200, 57600,
19200, 9600
● On Dell’s 12th generation PowerEdge and later systems: 115200, 57600, 19200,
9600
SYSCFG 97