CLI Guide

Table Of Contents
Table 162. SataPortF or sata5 (continued)
Example:
A:>syscfg --sata5=auto
sata5=auto
Applicable Systems All PowerEdge systems.
SataPortFCapacity
Table 163. SataPortFCapacity
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: NA
On Dells 12th generation PowerEdge and later systems: Read-only
Description
Displays the total capacity of a hard disk drive. This option is undefined for
removable-media devices such as optical drives.
Example:
A:>syscfg --SataPortFCapacity
Applicable Systems Dells 12th generation PowerEdge and later systems
SataPortFDriveType
Table 164. SataPortFDriveType
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: NA
On Dells 12th generation PowerEdge and later systems: Read-only
Description
This option indicates type of device attached to this SATA port.
Example:
A:>syscfg --SataPortFDriveType
Applicable Systems Dells 12th generation PowerEdge and later systems
SataPortFModel
Table 165. SataPortFModel
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: NA
On Dells 12th generation PowerEdge and later systems: Read-only
Description
Displays the drive model of the selected device.
Example:
A:>syscfg --SataPortFModel
Applicable Systems Dells 12th generation PowerEdge and later systems
SYSCFG 91