CLI Guide

Table Of Contents
Table 211. Proc
n
TurboCoreNum (continued)
Example:
A:>syscfg --Proc1TurboCoreNum=6
Proc1TurboCoreNum=6
Table 211. Proc
n
TurboCoreNum
Applicable Systems On Dells 13th generation PowerEdge and later systems
EnergyPerformanceBias
Table 212. EnergyPerformanceBias
Valid Arguments
On systems prior to Dells 13th generation PowerEdge systems: NA
On Dells 13th generation PowerEdge and later systems: MaxPower,
BalancedPerformance, BalancedEfficiency, LowPower
Description
Sets the Energy Efficient Policy. The CPU uses this setting to control the internal
behavior of the processor and to determine whether to target higher performance or
better power savings.
Example:
A:>syscfg --EnergyPerformanceBias=MaxPower
Applicable Systems Dells 13th generation PowerEdge and later systems
UncoreFrequency
Table 213. UncoreFrequency
Valid Arguments
On systems prior to Dells 13th generation PowerEdge systems: NA
On Dells 13th generation PowerEdge and later systems: DynamicUFS, MaxUFS,
MinUFS
Description
Sets the processor uncore frequency. Dynamic mode allows the processor to
optimize power resources across the cores and uncore during runtime. The
optimization of the uncore frequency to either save power or to optimize the
performance is dependent on the EnergyPerformanceBias option setting.
Example:
A:>syscfg --UncoreFrequency=DynamicUFS
Applicable Systems Dells 13th generation PowerEdge and later systems
System Security
You can manage the system security properties of the BIOS using the options in this group.
AcPwrRcvry or acpower
Table 214. AcPwrRcvry acpower
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: on, off, last
SYSCFG 107