CLI Guide

Example:
A:>syscfg --MemTest=Enabled
MemTest=Enabled
Applicable Systems All PowerEdge systems
NodeInterleave or nodeinterleave
Table 76. NodeInterleave or nodeinterleave
Valid Arguments
On systems prior to 12G: enable, disable
On 12G and later systems: Enabled, Disabled
Description
Enables node interleaving, if the system is congured with matching memory. If set to
disable (default), the system supports Non-Uniform Memory (NUMA) architecture
memory congurations. This eld is active only if the memory conguration can support
node interleaving.
NOTE: The nodeinterleave option is same as memintleave option. For more
information, see memintleave.
Example:
A:>syscfg --nodeinterleave=enable
nodeinterleave=enable
Applicable Systems All PowerEdge systems.
redmem
Table 77. redmem
Valid Arguments o, spare, mirror, DDDC
Description
Allows selection of the required redundant memory mode, or disables redundant memory.
This option can be replicated.
Example:
A:>syscfg --redmem=off
redmem=off
Applicable Systems PowerEdge systems with Intel Xeon 7500 series processor
SerialDbgOut
Table 78. SerialDbgOut
Valid Arguments
On systems prior to 12G: NA