CLI Guide
remashmedia
Table 292. remashmedia
Valid Arguments read-only
Description
Displays the redundancy status of internal dual SD module. The status can be:
• Full — Secure digital card (SD) 1 and 2 are functioning properly.
• Lost — Either any of the secure digital cards or both are not functioning properly.
The option also displays the status of the individual SD cards as follows:
• Active — The card is used for secure digital reads.
• Standby — The card is receiving a copy of all secure digital reads.
• Failed — An error is reported during a secure digital read or write.
• Absent — No secure digital media is detected.
• Oine — At boot, card identication signature is dierent from the non-volatile storage
value or card is the destination of a copying operation that is in progress.
• Write Protected — The card is write-protected.
Example:
A:>syscfg --remflashmedia
Internal Dual SD ModuleRedundancy=Lost
SD1 status=Absent
SD1 status=Active
Applicable Systems All systems prior to PowerEdge 12G systems
serial1
Table 293. serial1
Valid Arguments disable, com1, com3, com1_bmc, bmcserial, bmclan, rac
Description
Congures or reports the rst serial port communication port. This option can be replicated.
• bmcserial — maps serial port 1 to BMC Serial.
• bmclan — routes the serial trac destined for serial1 out to NIC1.
• com1_bmc — maps serial port 1 to COM port 1 BMC.
• rac — maps serial port 1 to the RAC device.
Example:
A:>syscfg --serial1=rac
serial1=rac
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
150 SYSCFG